Terminals
Input/Output
PHOTOCELLS
16 - 19
1
PAIR (N.C.)
st
(19= Common)
PHOTOCELLS
17 - 19
2
PAIR (N.C.)
st
(19= Common)
EMERGENCY
19 - 20
(N.C.)
(19= Common)
CLOSE/LATCHING
RELAY
(N.O.)
19 - 21
DIP # 7 on SW1 on
OFF
(19= Common)
CLOSE/LATCHING
RELAY
(N.O.)
19 - 21
DIP # 7 on SW1 on
ON
(19= Common)
22 - 23
NOT USED
SIDE SENSOR
22 - 24
(N.C.)
(22= Common)
STOP/
ANTI-PANIC
22 - 25
(N.C.)
(22= Common)
NOTE: The STOP lock/function blocks any movement in progress of the automation,
while the ANTI-PANIC lock/function stops the movement in progress of the auto-
mation and then resumes with a slow closing once the function is restored.
22
Door Status Function
Closed
None.
Opening
None.
Reverts motion and opens.
Closing
Open
Door won't close until photocells are released.
In pause
None.
None.
Closed
Opening
None.
Closing
Reverts motion and opens.
Door won't close until photocells are released.
Open
In pause
None.
Opens in any program, except in "LOCKED".
When dip # 1 on SW1 is set on ON opens also in
Closed
"LOCKED".
Opening
None.
Reverts motion and opens.
Closing
Open
Door won't close until input is released.
In pause
None.
None.
Closed
Opening
Reverts motion and opens.
Closing
None.
Closes in any program, except in "HOLD OPEN".
Open
In pause
None.
Closed
Opens in any program, except in "LOCK".
Reverts motion and closes, except in "HOLD OPEN".
Opening
Closing
Reverts motion and opens, except in "LOCK".
Closes in any program, except in "HOLD OPEN".
Open
IMPORTANT: Auto Close function is disabled.
In pause
Closes.
Closed
None.
Opening
Opening continues at reduced speed.
None.
Closing
Open
None.
In pause
None.
Closed
The door does not open so long as the input is busy.
Opening
It stops the automation.
Closing
It stops the automation.
Open
The door does not close so long as the input is busy.
The door does not open so long as the input is
busy. Once free, the door closes at reduced speed
In pause
after 5 seconds.
DC16