"SOLO USCITA"
(EXIT ONLY)
"ENTRAMBI I SNSI"
(AUTO)
"SEMPRE APERTA"
(HOLD OPEN)
"BLOCCATA CHIUSA"
(LOCK)
CONNECTIONS TO TERMINAL BOARD
CONNECTOR J2 - connector to TLINETD.
CONNECTOR J3 - optional.
CONNECTOR J4 - external accessory supply connection.
CONNECTOR J5 - encoder connection.
CONNECTOR J6 - transformer secondary connection.
CONNECTOR J7 - motor connection.
CONNECTOR J8 - input connection.
Terminals
Input/Output
AUX. DEVICES
8 - 11
POWER SUPPLY
SENSORS TEST
12 - 13
(12= 24V DC)
(13= - TEST)
Terminals
Input/Output
INSIDE SENSOR
14 - 19
(N.O.)
(19= Common)
OUTSIDE SENSOR
15 - 19
(N.O.)
(19= Common)
Exiting Traffic
Two-Way Traffic
Door remains always open
Door remains always
closed
Description
8= 24V AC
9= 24V AC
10= 24V DC
11= Common
Door Status Function
Closed
Opens in "EXIT ONLY" and "AUTO".
Opening
None.
Reverts motion and opens in "EXIT ONLY" and
Closing
"AUTO".
Open
Door won't close until sensor is released.
None.
In pause
Closed
Opens in "ENTRY ONLY" and "AUTO".
Opening
None.
Reverts motion and opens in "EXIT ONLY" and
Closing
"AUTO".
Open
Door won't close until sensor is released.
None.
In pause
DC16
Inside Radar
Close (Latching Relay)
Emergency
Outside Radar
Inside Radar
Close (Latching Relay)
Emergency
Emergency
Emergency Input
works only when dip
# 1 on SW1 is set
on ON
21