Bronpi BIO ELSA Instructions D'installation page 34

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 56
D10
D9
In drawing D11 are represented the basic requirements for the chimney installation of a thermo-stove:
Minimum height 1.5
Minimum height 1.5
D11
The flue must be away from flammable or combustible materials through an appropriate insulation or an air chamber. Inside the pipes, it is
forbidden the use of air abduction channels. It is also prohibited to do mobile or fixed openings for connecting other different equipments.
The smoke duct must be staunchness set to the equipment and it can have a maximum inclination of 45° whereby excessive deposits of
condensation produced in the initial stages of ignition and / or excessive soot formation is avoided. Moreover, it avoids the slowing down of
the smoke when it comes out.
The lack of sealing of the connection may cause the malfunction of the equipment.
The internal diameter of the connection pipe should correspond to the external diameter of the chimney of the equipment.
In drawing D12 you can see the requirements for a correct installation.
D12
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
33
ELSA, PAULA, BRENDA AND BRENDA-E

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bio paulaBio brendaBio brenda-e

Table des Matières