a. Connecting the video door phone
Carefully connect the wires according to the wiring diagram:
Connect the roadside panel to the input of the main distributor with a RJ45 cord.
Supply the roadside panel by connecting the P+ P- terminals to the P+ P- terminals of the power supply unit.
Connect the double cord (brown-blue) to the ML+ ML- terminals of the power supply unit (make sure to respect the po-
larity, brown wire to ML+ blue wire to ML-).
We count 1 distributor for 4 monitors, connect each monitor to a RJ45 input of the distributor.
In the event of several distributors, they must be connected to each other, by connecting the output 1° to the input 2° (etc...).
Supply the distributor(s) by connecting the P+ and P- terminals of the distributor(s) to the P+ P- terminals of the power
supply unit. Carefully observe polarity.
monitor 6
monitor 5
monitor 2
monitor 1
+
-
18 V DC lock
Caution! The power supply unit is foreseen for 1 camera + 10 monitors or 16 additional monitors.
Use the number of appropriate power supply unit.
Note it is possible to use additional monitors (max. 2 add.) per dwelling. See chapter 11, then leave free inputs on the dis-
tributors.
When the system is connected, connect the power supply unit to 230VAC (to an installation compliant with standards in
force, NFC 15-100 for France).
to the next distributor
distributor 2
(switch in HI position
if last distributor)
distributor 1
(switch in 120 position)
LK-TEST
ON OFF
SW3
L+
L-
L+
L-
ML+ML- P+ P-
L+
L-
L+
L-
ML+
ML-
P+
P-
UNLOCK
AC-IN
18V-OUT
DC-OUT
ON
SW1
OFF
PTR1
13~15V-OUT
VR1
power supply unit
100~240 V AC
CFI EXTEL WEVPMH 001 - 03/2010 - V1
monitor 8
monitor 7
monitor 4
monitor 3
ML-ML+
roadside panel/camera
P+
P-
back of the panel/
camera
7GB