(Maintain a clearance in the middle of the bracket for the connector) (4).
2. Connect the cable coming from the distributor to the connector (4) of the monitor.
3. Place the monitor (3) on the wall bracket (1).
Fig 7
5
WIRING
In order to avoid the risks of disturbances or dysfunction, do not put "low current" cables in the
same sheath as power cables.
Ethernet cable to use: 10 or 100 base T up to 200 m (max distance between roadside panel and last distributor), straight
wiring.
Types of cable, sizes, lengths maximum to use:
50m max
10/100base T
50m max
10/100base T
50m max
10/100base T
2x1.5mm
2
gate opener
CFI EXTEL WEVPMH 001 - 03/2010 - V1
6GB
50m max
10/100base T
50m max
10/100base T
50m max
10/100base T
2x1.5mm
2
200m max
4x1.5mm
2
50m max
roadside panel/camera
a. Connecting the video door phone
Carefully connect the wires according to the wiring diagram:
Connect the roadside panel to the input of the main distributor with a RJ45 cord.
Supply the roadside panel by connecting the P+ P- terminals to the P+ P- terminals of the power supply unit.
Connect the double cord (brown-blue) to the ML+ ML- terminals of the power supply unit (make sure to respect the po-
larity, brown wire to ML+ blue wire to ML-).
We count 1 distributor for 4 monitors, connect each monitor to a RJ45 input of the distributor.
In the event of several distributors, they must be connected to each other, by connecting the output 1° to the input 2° (etc...).
Supply the distributor(s) by connecting the P+ and P- terminals of the distributor(s) to the P+ P- terminals of the power
supply unit. Carefully observe polarity.
Fig 8
Caution! The power supply unit is foreseen for 1 camera + 10 monitors or 16 additional monitors.
Use the number of appropriate power supply unit.
Note it is possible to use additional monitors (max. 2 add.) per dwelling. See chapter 11, then leave free inputs on the dis-
tributors.
When the system is connected, connect the power supply unit to 230VAC (to an installation compliant with standards in
force, NFC 15-100 for France).
to the next distributor
distributor 2
(switch in HI position
monitor 6
if last distributor)
monitor 5
distributor 1
monitor 2
(switch in 120 position)
monitor 1
ON OFF
LK-TEST
SW3
L+
L-
L+
L-
ML+ML- P+ P-
ML-ML+
L+
L-
L+
L-
ML+
ML-
P+
P-
UNLOCK
AC-IN
18V-OUT
DC-OUT
ON
SW1
OFF
PTR1
13~15V-OUT
+
-
P+
P-
VR1
18 V DC lock
power supply unit
back of the panel/
100~240 V AC
camera
CFI EXTEL WEVPMH 001 - 03/2010 - V1
monitor 8
monitor 7
monitor 4
monitor 3
roadside panel/camera
7GB