1 Online user manual
2 Specifications
on page 3
3 General information
4 Installation
on page 7
Section 1 Online user manual
This Basic User Manual contains less information than the User Manual, which is available on the
manufacturer's website.
Section 2 Specifications
Specifications are subject to change without notice.
Specification
Component description Microprocessor-controlled and menu-driven controller that operates the
Operating temperature
Storage temperature
Enclosure
European standards
ETL approved
Power requirements
Altitude requirements
Pollution degree /
Installation category
Outputs
Relays
Dimensions
on page 3
on page 4
Details
sensor and displays measured values.
-20 to 60 ºC (-4 to 140 ºF); 95% relative humidity, non-condensing with
sensor load <7 W; -20 to 50 ºC (-4 to 104 ºF) with sensor load <28 W
-20 to 70 ºC (-4 to 158 ºF); 95% relative humidity, non-condensing
NEMA 4X/IP66 metal enclosure with a corrosion-resistant finish
EN 61326-1: 2006; EN 61010-1:2010
File 65454
AC powered controller: 100-240 VAC ±10%, 50/60 Hz; Power 50 VA
with 7 W sensor/network module load, 100 VA with 28 W sensor/network
module load (optional Modbus RS232/RS485 or Profibus DPV1 network
connection).
24 VDC powered controller: 24 VDC—15%, + 20%; Power 15 W with
7 W sensor/network module load, 40 W with 28 W sensor/network
module load (optional Modbus RS232/RS485 or Profibus DPV1 network
connection).
Standard 2000 m (6562 ft) ASL (Above Sea Level)
Pollution Degree 2; Installation Category II
Two analog (0-20 mA or 4-20 mA) outputs. Each analog output can be
set to 0-20 mA or 4-20 mA, and can be assigned to represent a
measured parameter such as pH, temperature, flow or calculated values.
Optional 3 additional analog outputs. Secure Digital Memory card for use
in data logging and software updates.
Four SPDT, user-configured contacts, rated 5A 250 VAC (resistive).
Contacts are rated 250 VAC, 5 Amp resistive maximum for the AC
powered controller and 24 VDC, 5A resistive maximum for the DC
powered controller. Relays are designed for connection to AC Mains
circuits (i.e., whenever the controller is operated with 115 - 240 VAC
power) or DC circuits (i.e., whenever the controller is operated with
24 VDC power).
½ DIN—144 x 144 x 180.9 mm (5.7 x 5.7 x 7.12 in.)