Before using the nebulizer group, carefully read all of the instructions and follow them scrupulously. The
manufacturer cannot be held responsible for damage to persons and/or property caused by improper use of the
equipment.
This use and maintenance manual is an integral part of the equipment and must therefore be stored carefully
and passed on with the unit in the event of a change of ownership.
THE EQUIPMENT MUST BE HOOKED UP TO THE POWER MAINS USING THE RESIDUAL CURRENT CIRCUIT
•
BREAKER WITH SENSITIVITY NOT EXCEEDING 30 mA AND CAPACITY RATED FOR THE POWER OF THE
MACHINE (SEE DATA SHEET)
THE MINIMUM WATER SUPPLY FLOW RATE MUST NOT BE BELOW THAT INDICATED ON THE DATA SHEET
•
THE WATER SUPPLY PRESSURE MUST NOT EXCEED 3 bar. IF HIGHER, A SUITABLE PRESSURE REDUCER
•
MUST BE INSTALLED.
EQUIPMENT NOT SUITABLE FOR CONNECTION TO THE DRINKING WATER MAINS: THE NEBULIZER GROUP
•
CANNOT BE CONNECTED DIRECTLY TO THE DRINKING WATER DISTRIBUTION NETWORK WITHOUT HAVING
INSTALLED AN ANTI-BACKFLOW DEVICE IN THE SUPPLY PIPE WITH EMPTYING CAPACITY COMPLIANT WITH
CURRENT REGULATIONS. A REINFORCED PIPE WITH A DIAMETER OF AT LEAST Ø13MM - ½ INCH IS ALSO
REQUIRED.
WATER PASSING THROUGH ANTI-BACKFLOW DEVICES CANNOT BE CONSIDERED DRINKABLE.
•
USE ONLY FILTERED OR CLEAN WATER, PLACING THE NEBULIZER GROUP AS CLOSE AS POSSIBLE TO THE
•
WATER SUPPLY MAINS. THE WATER SUPPLY TAP MUST ALSO GUARANTEE A SUPPLY EQUAL TO TWICE
THE MAXIMUM FLOW RATE OF THE PUMP.
L-LC191.01.BM
EN
IMPORTANT
WARNING
WARNING
37 / 72