CE conformity mark
1. Technical Data
Use for the intended purpose
WARNING
Only use the ROLLER'S Ortem 22/32 pipe cleaning machine for the intended purpose
of cleaning pipes and drains.
All other uses are not for the intended purpose and are prohibited.
1.1. Article numbers
ROLLER'S Ortem 22 drive unit with guide hose
ROLLER'S Ortem 32 drive unit with guide hose
Adapter drum Ortem 22/8
Adapter drum Ortem 32/8
Guide gloves, pair
Riveted guide glove, left
Riveted guide glove, right
Guide hose Ortem 22
Guide hose Ortem 32
Drain cleaning cables
Drain cleaning cable 8 × 7.5 m
Drain cleaning cable 16 × 2.3 m
Drain cleaning cable 22 × 4.5 m
Drain cleaning cable 32 × 4.5 m
Drain clean. cable 16 × 2.3 m (6 pcs.) in cable carrier
Drain clean. cable 22 × 4.5 m (5 pcs.) in cable carrier
Drain clean. cable 32 × 4.5 m (5 pcs.) in cable carrier
Drain cleaning cable S 16 × 2 m
Drain cleaning cable S 22 × 4 m
Drain cleaning cable S 32 × 4 m
Drain cleaning cable with core 16 × 2.3 m
Drain cleaning cable with core 22 × 4.5 m
Drain cleaning cable with core 32 × 4.5 m
Cable reduction 22/16
Cable reduction 32/22
Cable carrier 16 (empty)
Cable carrier 22 (empty)
Cable carrier 32 (empty)
Cable joint separator 16
Cable joint separator 22/32
Drain cleaning tools
Straight auger 16
Straight auger 22
Straight auger 32
Bulbous auger 16
Bulbous auger 22
Bulbous auger 32
Funnel auger 16
Funnel auger 22
Funnel auger 32
Retrieving auger 16
Retrieving auger 22
Retrieving auger 32
Serrated blade borer 16/25
Serrated blade borer 22/35
Serrated blade borer 22/45
Serrated blade borer 32/55
Serrated cross-blade borer 16/25
Serrated cross-blade borer 16/35
Serrated cross-blade borer 22/35
Serrated cross-blade borer 22/45
Serrated cross-blade borer 22/65
Serrated cross-blade borer 32/45
Serrated cross-blade borer 32/65
Serrated cross-blade borer 32/90
Serrated cross-blade borer 32/115
Forked cutter 16
Cross-forked cutter 16
Serrated forked cutter 22/65
Serrated forked cutter 32/65
Serrated forked cutter 32/90
Root cutter 22/65
Root cutter 32/65
Root cutter 32/90
Chain flail 16, smooth rings
Chain flail 16, spiked links
Chain flail 22, smooth rings
Chain flail 22, spiked links
Chain flail 32, smooth rings
Chain flail 32, spiked links
1.2. Working range
ROLLER'S Ortem 22
Cable Ø 8 mm (max. working length 10 m)
Cable Ø 16 mm (max. working length 40 m)
Cable Ø 22 mm (max. working length 70 m)
ROLLER'S Ortem 32
Cable Ø 8 mm (max. working length 10 m)
Cable Ø 16 mm (max. working length 40 m)
Cable Ø 22 mm (max. working length 100 m)
Cable Ø 32 mm (max. working length 70 m)
1.3. Working speed
172000
Working spindle
174000
1.4. Electrical data
170011
Rated voltage
170012
Power input
172610
Rated current
172611
Intermittent service
172612
Protection class
044110
1.5. Dimensions (L × W × H)
044105
Drive unit
170200
1.6. Weights
171200
ROLLER'S Ortem 22 drive unit
172200
ROLLER'S Ortem 32 drive unit
174200
Tool set 16
171201
Tool set 22
172201
Tool set 32
174201
Cable set 6 × 16 × 2.3 m in cable carrier
171205
Cable set 5 × 22 × 4.5 m in cable carrier
172205
Cable set 4 × 32 × 4.5 m in cable carrier
174205
171210
1.7. Noise information
172210
Emission at workplace
174210
172154
1.8. Vibrations
174154
Weighted effective value
171150
of acceleration
172150
The indicated weighted effective value of acceleration has been measured
174150
against standard test procedures and can be used by way of comparison with
171151
another device. The indicated weighted effective value of acceleration can also
172151
be used as a preliminary evaluation of the exposure.
Attention: The indicated weighted effective value of acceleration can differ
171250
during operation from the indicated value, dependent on the manner in which
172250
the device is used. Dependent upon the actual conditions of use (periodic duty)
174250
it may be necessary to establish safety precautions for the protection of the
171265
operator.
172265
2. Putting into Service
174265
171270
2.1. Electrical connection
172270
174270
WARNING
171275
Ensure that the mains voltage is correct! Before connecting the unit, check
172275
that the mains voltage is the same as specified on the rating plate. Only operate
174275
the machine off the mains using a 30 mA fault current protected switch (FI
171280
breaker).
172280
172281
2.2. Handling and selection of the drain cleaning cable required
174282
The machines ROLLER'S Ortem uses lengths of cable which can be connected
171290
up as necessary. The machine ROLLER'S Ortem 22 comes either with the tool
171291
set 16 or 22 or both. The machine ROLLER'S Ortem 32 comes either with the
172290
tool set 22 or 32 or both. The cables can each be used without any modifica-
172291
tions to the machine.
172293
For the ROLLER'S Ortem 32 machine, the cable and tool set 16 can also be
174291
used when using other clamping jaws 16 (accessories). To do this, remove
174293
protecting device (2). Push in the spring brush until it touches using a screw
174295
driver. Push the whole clamping jaw forward and lift out backwards over the
174296
spiral pin. Fit clamping jaw 16 (set), Art.-No. 174101. Then push clamping jaw
171305
16 into the system bearer, push in the spring brush until it touches and push
171306
the clamping jaw over the spiral pin.
172305
The cables are specially hardened and highly flexible, and can be quickly
174305
extended or shortened by means of T-groove safety connectors.To connect
174306
two lengths, push the T-bar (7) sideways into the T-groove (8). The spring-loaded
172310
thrust pin in the T-bar component locks the two halves together. To separate
174310
them, push back the spring-loaded thrust pin with the releasing tool (9) and
174311
push the T-bar out of the T- groove. The cables and tools will also fit other makes
171340
of drain cleaning machines. An adapter drum for ROLLER'S Ortem 22 and
171341
ROLLER'S Ortem 32 each with a Ø 8 mm cable, length of 7.5 m, can be supplied
172340
as accessory (see 3.4.).
172341
174340
The diameter of the cable required depends on the diameter of the pipe to
174341
be cleaned. For guidance see 1.2.
The type of cable required depends on the length and position of the pipe
concerned and the type of obstruction expected. The standard cable is used
for general drain cleaning operations. Being highly flexible, it is particularly
Pipe Ø 10 – 50 (75) mm
Pipe Ø
20 – 100 mm
Pipe Ø
30 – 150 mm
Pipe Ø 10 – 50 (75) mm
Pipe Ø
20 – 100 mm
Pipe Ø
30 – 150 mm
Pipe Ø
40 – 250 mm
Ortem 22
Ortem 22
740 ¹/min
520 ¹/min
230 V 1~; 50 Hz
230 V 1~; 50 Hz
750 W
1050 W
3.3 A
5.8 A
S3 40% 4/10 min
S3 40% 4/10 min
IP 44 F
IP 44 F
535 × 225 × 535 mm
535 × 225 × 595 mm
21" × 8.9" × 21"
21" × 8.9" × 23.4"
19.1 kg (42.2 lb)
24.6 kg (54.6 lb)
1.8 kg (4.0 lb)
2.3 kg (5.1 lb)
1.9 kg (4.2 lb)
7.4 kg (16.4 lb)
20.6 kg (45.7 lb)
26.3 kg (58.4 lb)
Ortem 22
Ortem 22
75 dB (A)
75 dB (A)
2.5 m/s²
2.5 m/s²