Commissioning
Installation
Package Contents
Check the shipment for transport damage and completeness.
• Voltage presence detector in transport packaging
• Washers and self-locking nuts (M5) for high voltage connection
• 2-pin connector (push-in) for power supply
• 8-pin connector (push-in) for output
• Documentation
• Specific test report
For voltage presence detectors with protective covers (ZU 1030):
• Protective cover for input
• Protective cover for output/power supply
• 2 cable support sleeves for high-voltage cables
Mounting
• On a plane mounting surface
For use on rolling stock, we recommend mounting the device on a plane
mounting surface using 4 screws (M6). Fasten the M6 screws with a recom-
mended tightening torque of 2 Nm on the plane (conducting or
non- conducting) mounting surface (see L in fig. on page 53).
• On a DIN rail
Snap it onto a TS 35 DIN rail or mount on a plane surface.
CAUTION! Protection and safety functions:
Inside rolling stock, the voltage presence detector must be installed in
closed and fire-protected enclosures. They must meet the following
requirements of EN 45545-2 4.2 (h):
– Control cabinet volume ≤ 2 m
– Control cabinet volume > 2 m
insulation capacity I15 (surfaces adjacent to compartments
for passengers or personnel)
– Alternatively, protected by a fire alarm/extinguishing system in the
installation space
3
: Proof of fire resistance E10
3
: Proof of fire resistance E15,
49