44. Technical data

Gateway
Network technology
Radio technology
Frequency
Antenna
Input voltage
Enclosure/protection rating
Cable connection
Electrical connection
Operating temperature/
humidity
Weight (without antenna)
Multi-button
Radio transmitter
Energy generation
Frequency
Transmission range
Dimensions
Operating temperature/humidity -25−65 °C/max. 85%
EN
Repeater
Radio technology
Frequency
Antenna
Input voltage
Enclosure/protection rating
Electrical connection
Operating temperature/
humidity
Weight (without antenna and
transformer)
78
CTC SmartControl
RS-485 Modbus
EnOcean (IEC 14543-3-10)
868 MHz
External, 2.5 m cable
12 V DC via display
PA6.6/IP42 according to EN
60529
M20 for max. cable diameter
= 8 mm
Terminal block, max 1.5 mm
2
-20−60 °C/max. 85% rH
110 g
Integrated, EnOcean PTM
200
Electrodynamic energy
generator, maintenance-free
868 MHz
RPS type 2, 300 m without
obstacles, approx. 30 m
indoors
Central plate: 51 x 51 mm
EnOcean (IEC 14543-3-10)
868 MHz
External (2.5 m cable)
230 V AC via power supply
PA6.6/IP65 according to EN
60529
Terminal block, max 1.5 mm
2
-20−60 °C/max. 70%
110 g
Room sensor
Measurement
Radio technology
Frequency
Measurement interval
Voltage source
Enclosure/protection rating
Operating temperature/humidity -0−40 °C/max. 85% rH
Weight
Room/humidity sensor
Measurement
Radio technology
Frequency
Voltage source
Measurement interval
Threshold values rH %
ventilation mode Forced
ventilation mode Customised
Enclosure/protection rating
Operating temperature/
humidity
Weight
Room/humidity/CO
Measurement
Radio technology
Frequency
Input voltage
Measurement interval
Threshold values (CO
) ppm:
2
ventilation mode Forced
ventilation mode Customised
Threshold values (rH) % :
ventilation mode Forced
ventilation mode Customised
Enclosure/protection rating
Operating temperature/
humidity
Weight
Temperature
EnOcean (IEC 14543-3-10)
868 MHz
100 s (default)
Solar cells (battery
operation possible)
ASA (thermoplastic)/IP30
according to EN 60529
50 g
Temperature, relative
humidity
EnOcean (IEC 14543-3-10)
868 MHz
Solar cells (battery
operation possible)
100 s (default)
Start: 65, stop: 55
Start: 70, stop: 60
ASA (thermoplastic)/IP30
according to EN 60529
-0−40 °C/max. 85% rH
50 g
sensor
2
Temperature, relative
humidity, CO
level
2
EnOcean (IEC 14543-3-10)
868 MHz
230 V AC via power supply
100 s (default)
Start: 1,000, stop: 800
Start: 1,200, stop: 1,000
Start: 65, stop: 55
Start: 70, stop: 60
ASA (thermoplastic)/IP30
according to EN 60529
-0−40 °C/max. 85% rH
90 g