EN
A
PICTURES
[1] 1 AC Motor Controller WM 100-230 V AC,
wall mounted version
[2] 1 AC Motor Controller PCB 100-230 V AC,
PCB version (with DIN rail clip, Ref. 9008049)
B
MOUNTING
[1] Choose the optimal location: flat and large surface
or electric cabinet. Close door!
[2] Use cable tie!
[3] Mount the 1 AC Motor Controller WM
[4] Mount the DIN rail version
1.
Vertical (wall mounted or PCB version)
2.
Horizontal (wall mounted version)
C
WIRING
[1] Connect power supply and wiring to the
Motor Controller
[2] Insulated screwdriver
[3] Wiring diagram
[4] Check the correct running directions of the end product
UP: the end product goes up ( C + s)
STOP: the end product stops ( C + t+ s)
DOWN: the end product goes down ( C + t)
n To close window press UP,
to open window press DOWN.
[5] Possible switches
1.
Smoove Origin IB, Ref. 1811272
2.
Double push button
D
CONFIGURATION
[1] Reset / Prog button
With this button, you can access the basic
configuration of the Motor Controller.
1.
Wall mounted version
2.
PCB version
CABLE
Connection to ...
Motors
Switch
Group control
100-230 V AC
Cables
Min.: 4 x 0.75 mm
/18 AWG
2
Max.: 4 x 2.5 mm
/14 AWG
2
Min.: 3 x 0.6 mm/22 AWG
Max.: 3 x 2.5 mm
/14 AWG
2
Min.: 4 x 0.6 mm/22 AWG
Max.: 4 x 1.5 mm
/16 AWG
2
Min.: 3 x 1.5 mm
/16 AWG
2
Max.: 3 x 2.5 mm
/13 AWG
2
[2] Selection of switch ergonomic
Local push button ergonomics and the type of end
products to be preselected:
• Screen mode
• Venetian blind, European mode (default mode)
• Venetian blind, US mode
1.
To toggle between modes, press the Reset / Prog
button 2 s. Repeat until the LED, according to
the desired configuration, lights up. Store by
pressing 2 s.
[3] Factory RESET
[4] Learn running time/length
1.
Drive screen to upper end limit
2.
Press Stop until screen drives down on its own
3.
Press Stop when lower end limit is reached
[5] Symbols: actions
1.
Up
2.
Stop
3.
Down
[6] Symbols: end product status
1.
Up
2.
Upper end position
3.
Down
4.
Lower end position
m When electronic motors are to be controlled through this
Motor Controller device it is mandatory to configure the start-
up delay time for electronic motors in the Motor Controller
settings. To configure the start-up delay time WT Setting Tool
Ref. 1811242 can be used.
Twisted pairs
-
Recommended
Recommended
-
animeo IB+ 1 AC MOTOR CONTROLLER. REF. 5047280E -
Max. distance
150 m
100 m
1000 m