5.2

AC DISTRIBUTION

Model
Input
Voltage
Frequency
Current intensity 230/115VAC
Input circuit breaker
Output
Voltage
frequency
Number of outputs
Output current
Output circuit breaker
5.3
CHARGER FUNCTION, MODEL: CPS3 12V/16A, 12V/25A AND 12V/40A
Model
Input
Voltage
Frequency
Current intensity 230/115VCA
Power factor
Efficiency
Input fuses F1/F2
Output
Number of outputs
Total rated current (+/-7%) / rated power
Load curve
Batteries type
Regulated and filtered output voltage
Regulation tolerance before distributors and
fuses
Peak-to-peak ripple and noise
Automotive output fuses mounted in parallel
in the BAT pole -
Electrical protections
UECPS3-12-16/25/40-DEA.DOC
12V-16A
From 85 to 265VCA single-phase. The earth-leak circuit breaker test button does
not operate for voltages below 185VCA.
From 47 to 65Hz
< 16A (depending on output's consumption)
16A bipolar earth-leak circuit breaker
= input voltage
= input frequency
2,3 or 4 depending on model
10A per output max
Added max total =16A
Circuit breaker Ph+N, 10A
Number : 2, 3 or 4 depending on model
12V-16A
From 85 to 265VCA single phase
From 47 to 65Hz
1.4A/2.9A
0,9 (in rated conditions)
> 80% (in rated conditions)
2x6,3A/250V Ref. DEL MICRO
FUS 00346623MST (F1/F2)
3 separated outputs BAT D, BAT 1 and BAT 2 (integrated distributor)
Each output can be used on its own and supply the entire current.
16A/228W
Selected type of charge IU or IUoU (Boost, Absorption, Floating – factory setting).
See selection wheel setting table
See selection wheel setting table. The chargers can operate on DC supply.
< 2% (in rated conditions)
< 2% (in rated conditions)
1 x 20A/32V (F3)
- Against leaking input surges by rupture of VDR (voltage-dependent resistor) (not
covered by warranty)
- Against output polarity reversals by rupture of fuses
- Against output short-circuits and surges
- Against abnormal overheating by cutting off the charger (internal temperature probe
90°C) – Automatic re-start
- Against output surges (17V
12V-25A
12V-25A
2A/4.2A
2 x T15A/250V
6,3x 32 (F1/F2)
25A/356W
1 x 30A/32V (F3)
±5%)
12V-40A
12V-40A
3,2A/6,6A
40A/570W
2 x 25A/32V
(F3/F4)
28