1 PRECAUTIONS – WARRANTY
The Cristec equipment includes the following:
1 metal box containing the battery charger's electronic functions, the 230VAC protection circuit
breakers and one AC power plug
This operating manual
This document applies to shore-power units from the CPS3 CRISTEC range as listed on the cover.
The manual is intended for users, installers and equipment maintenance staff. Please read this manual carefully
before working on the shore-power unit.
This manual should be kept safely and consulted before attempting any repairs, because it contains all the
information required to use the appliance.
This document is the property of CRISTEC; all the information it contains applies to the accompanying
product. CRISTEC reserves the right to modify the specifications without notice.
1.1
PRECAUTIONS
Precautions regarding overheating of the appliance
This appliance is designed to be mounted on a vertical wall or partition as indicated herein.
It is imperative that there be a gap of 150mm around the shore-power unit. The installer must see to it that the
temperature of the air at the input is lower than 40°C in extreme operating conditions.
Measures should also be taken to allow for the discharge of hot air on either side of the shore-power unit.
The shore-power unit must not be installed near a source of heat; it should be installed in a well-ventilated area.
The shore-power unit's air inlets and outlets must not be obstructed.
Precautions regarding dust, seepage and falling water
The shore-power unit should be located so as to prevent penetration of damp, liquids, salt and dust, any of
which could cause irreparable damage to the equipment and be potentially hazardous for the user.
The appliance should be installed in a dry and well-ventilated place.
Precautions regarding inflammable materials
The shore-power unit should not be used near inflammable materials, liquids or gases.
The batteries can emit explosive gases: please follow the manufacturer's instructions carefully when installing
them.
Precautions regarding accidental earthing leaks
The PE terminal must be earthed and connected before any of the other terminals (see relevant diagram in the
appendix).
The shore-power unit must be closed before it is turned on: the cover must be fixed to the shore-power unit's
body with the screw provided for the purpose.