3.2.6 Precautions regarding electromagnetic disturbance generated by the appliance
Use shielded cables for all the connections (*). The shielding should be earthed at both the transmitting and
the receiving ends.
Keep cable length and shielding connections down to a minimum.
Route cables as close as possible to conductive parts ("loose" cables or loops should be avoided – cables
should be flattened against conductive parts).
Keep power cables separate from battery cables.
Keep power cables separate from control cables (at least 200mm).
The cables should only supply power to this appliance; any branch-off or short-out intended to power
another appliance are prohibited.
(
)
*
This is a recommendation for installation rather than an obligation. The installing electrician should
decide whether or not to use shielded cable depending on the EMC environment.
3.2.7 Principle of battery wiring (charger function)
3.2.7.1 Cabling type
Entrée AC
AC input
Connexion batteries
3.2.7.2 Other type of installation
Refer to appendix p : 37.
3.3
SELECTION WHEEL AND SWITCH SETTINGS – ADJUSTMENT – INDICATORS
(CHARGER PART)
3.3.1 Description
The CPS3 shore power units are equipped with a selection wheel (RC1) allowing setting up the charger
according the battery type and the application.
UECPS3-12-16/25/40-DEA.DOC
Chargeur 3 Sorties
/ 3 Output charger
(si configuration en chargeur)
Batterie démarrage moteur
Engine start-up battery or less-used battery
/ Battery connections
(si configuration en chargeur)
(in case of charger setting)
ou batterie la moins sollicitée
Batterie auxiliaire BAT 1
Auxiliary battery BAT 1
Toutes les sorties ne sont pas obligatoirement à connecter
Not all the outputs have to be connected
(in case of charger setting)
Batterie auxiliaire BAT 2
Auxiliary battery BAT 2
08-02-2013 N°12268 11A
23