Setting thanks to a small flat head screw driver (width 2,5mm) and turn in clockwise direction.
RC1: Selection of the load curves
The CPS3 shore power units are equipped with a Boost function for a faster charge of the batteries. This
function is controlled by a timeout (see table here after) and is automatically inhibited when the battery is
fully charged: stoppage of the boost for I batteries < 15% of I rated charger.
The Boost function can be disabled by using the RC1 selection wheel (setting B, C,D or E).
3.3.2 Settings according to the type of battery
Description of the battery type
RC1 setting
or setting
0
Opened type bat free electrolyte
1
Classic sealed type bat (Lead sealed)
(factory setting)
2
GEL type bat
3
AGM type bat
4
Tin calcium lead bat
5
Spiral type bat
6
Opened bat Wintering
7
Wintering or standby sealed bat
8
Specific setting 1 (GEL+)
9
Specific setting 2 (GEL SP)
A
Specific setting 3 (AGM+)
B
Specific setting 4
C
Specific setting 5
D
Specific setting 6
E
Specific setting 7
F
Direct current power supply
(*) Voltage on BAT 1 / BAT 2 with 10% of the rated current and a tolerance of +/- 1%.
The voltage on +BATD is lower than 0,2V (approx.) at 10% of the charger rated current and 0,4V
(approx.) at 100% of the charger rated current.
The voltage on +SP is higher than 0,3V (approx.) at 10% of the charger rated current and 0,4V (approx.)
at 100% of the charger rated current.
UECPS3-12-16/25/40-DEA.DOC
(
)
*
Voltage
Floating phase
13,4V
13,8V
13,8V
13,6V
14,4V
13,6V
13,2V
13,4V
13,8V
13,8V
13,6V
13,4V
13,8V
13,6V
14,4V
12,5V
Maximum duration of
(
)
*
Voltage
BOOST at
BOOST phase
14,1V
14,4V
14,4V
14,4V
15,1V
14,4V
14,4V
14,2V
14,4V
+
/- 5%
T
BOOST
2H
6H
4H
4H
4H
6H
0H
0H
8H
4H
8H
0H
0H
0H
0H
0H
24