12. Technical data
Environmental
Ingress protection IP 65/NEMA4 with closed cover
conditions,
Vibration security IEC 654-3, v<3mm/s, 1<f<150 Hz
continued
EMC/Immunity
RF protection
Interference safety
-ESD
-Electromagnetic
fields
-Burst (supply
circuit)
-Burst (signal
circuit)
-Surge,
HF discharge
-Normal mode
noise rejection
Housing
Dimensions
construction
Weight
Material
Electrical
connections
Display and
Display
operating level
Operating level
Power supply
Power supply
Battery life cycle
Certificates
CE
Technical alterations reserved
42
To EN 55011 Group 1, Class B
To EN 61000-4-2, Level 3, 6/8 kV
To EN 61000-4-3, Level 3,103 V/m
To EN 61000-4-4, Level 3, 1 kV / 2 kV
To EN 61000-4-4, Level 3, 1 kV
To EN 61000-4-6, 10 V
additional measurement accuracy ≤ 0.5%
26 dB at input range/10, f = 50/60 Hz, not on
resistance measurement
W: 100 mm / H: 100 mm / D: 60 mm
approx. 0.520 kg
Housing: Aluminium die cast, surface galvanised
Wall/stand pipe adapter: 1.4301
Strap: 1.4301
Two wire connection (three wire on Pt 100).
Connection access using 2 PG 9 cable glands
(optionally 1 x ½
" NPT thread instead of 1 x PG9).
Termination on 2,5 mm
ferrule.
LC-Display, 7 segment, prefix, decimal point, limit
symbol, battery status symbol
PC software package for setting up , transmission
and display of measured data. Software will run
under Windows 3.11/9x/NT/2000.
Lithium battery 3.6 Volt Type AA, optionally Type C or
external power supply 7 ... 30 VDC, approx. 5 mA
Monthly readout:
Continuous readout: min. 1 month
89/336/EWG guide lines
2
terminals, 1,5 mm
Type AA (2,1 Ah)Type C (7,2 Ah)
min. 2 Years
min. 5 Years
min. 2 month
2