Grounding the Switch
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI).
Run the ground connection from the ground screw to the grounding surface prior to connecting
devices.
NOTE:
This product is intended to be mounted to a well-grounded mounting surface such
as a metal panel.
DC Input: 12-48V ,1.25A max.
AC Input: 24V~,0.7A max.
Connecting the Power
The Upper Panel of the switch indicates an AC/DC inlet power socket and consists of one terminal
block connector within 6 contacts. Please follow the steps below to insert the power wire.
1. Insert positive/negative AC or DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5
and 6 for Power 2.
DC Input: 12-48V,1.25A max.
AC Input: 24V~,0.7A max.
6
Max. fault loading: 24V,1A
1
2 3 4 5 6
V1+ V1
V2+ V2
DC Input: 12-48V,1.25A max.
AC Input: 24V~,0.7A max.
PWR1
Fault
PWR2
1
2 3 4 5 6
V1+ V1
PWR1
Max. fault loading: 24V,1A
1
2 3 4 5 6
V1+ V1
V2+ V2
PWR1
Fault
PWR2
V2+ V2
PWR2
Fault
1 2 3 4 5 6
V1+ V1
PWR1
Fault
12-48VDC,24VAC
V2 + V2
PWR2