ENGLISH
Table 1: Menu structure
Menu point
Standard display:
P:4,3bar
V:100%
P: Current system pressure on pressure side
V: Cistern filling volume
> Automatic
rw<
RW: Rainwater from cistern
DW: Drinking water from backfeed tank
1 select
operational mode
Selection of unit operating mode
1.01 mode
(see chapter 4.1)
> automatic
<
Manual function for pump. Switches on pump for
1.02 pump manu.
as long as key is pressed (F or G)
Only in Manual operating mode (menu 1.01)
> OFF
<
Manual function for valve. Opens valve for as
1.03 valve manu.
long as key is pressed
Only in Manual operating mode (menu 1.01)
> OFF
<
2 equipment
configuration
Displays unit's software version Vx.xx
2.01 WILO RCE
Vx.xx dd.mm.yyyy
and date of issue dd.mm.yyyy.
Selection of menu language
2.02 language
> English
<
2.03 sensor typ
Selection of level sensor used
H
max
> 5,00 m
<
of the measuring range
2.04 tank form
Selection of available tank form
> verti.cylin. <
Specification of tank height
2.05 tank height
> 199 cm
<
Installation height of sensor above tank bottom.
2.06 h sensor
Absolute value measured in relation to tank
bottom.
> 025 cm
<
Installation height of overflow above tank bottom
2.07 h overflow
Absolute value measured in relation to tank
bottom.
> 091 cm
<
14
(Attention: observe notes under point 4)
Description
corresponds to the upper limit (2 or 5 mWS)
Setting range
Factory setting
Automatic
Automatic
OFF
manual
drinkwater
ON
OFF
OFF
ON
OFF
OFF
Deutsch
Deutsch
English
Nederlands
Francais
> 2.00 m
<
5.00 m
> 5.00 m
<
base x heigth
vertical cylinder
horizontal cylinder
vertical cylinder
spherical
00 – H
[cm]
199 cm
max
00 – H
[cm]
025 cm
max
(but less than
2.05)
00 – H
[cm]
091 cm
max
but greater than
2.06 and less 2.05