Different Windows; Start Window - SEFRAM TR1500 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Click on the « Conf» icon
Program a simple set-up for instance :
Select at least one channel (key 4 figure 1)
Acquisition rate 1s
No alarm
Immediate start
stop : memory full
Click on send set-up
Click on the « start » icon
The measurements of the datalogger are launched.
Check that the green « led » is flashing (pilot light of measurement in progress)
The text box at the top right (9 figure 1) specifies the status of the datalogger : « measurement in progress »
or « in stand-by »
Wait for a few measurements
Click on the « stop » icon
The measurements stop
The text box at the top right (9 figure 1) specifies the status of the datalogger : « measurement stopped :»
and the number of measurements performed.
Click on the « read » icon
The measurements performed are transferred to the PC and displayed on the graph.
Click on the « Save » icon
If you wish to save the measurements in a T15 type file.

11 Different windows

11.1 Start window

The start screen is displayed for 4 seconds and gives the version number of the TR1500 software.
MTR15001F/03
Page 14 / 24
Sefram
Groupe General Electronique Mesure

Publicité

Chapitres

Table des Matières
loading

Table des Matières