Spare Parts; Electrical Diagram; Disposal; Ce Declaration - PLYMOVENT MFS Manuel Opérateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
Symptom
problem
Dust or
Pollution of
smoke coming
the facility.
out of the
filter cover.
Dust or
Pollution of
smoke coming
the facility.
from dust
tray.
Vibrations in
Machine not
the machine.
steady.
8

SpaRE paRTS

The following spare parts are available for the machine (refer
to exploded view Fig. I on page 56).
article no.
Description
MFS and MFS/C general
0000102271
Magnetic valve
0000102277
Control light 28V, yellow
0000102283
PC board control
0000102284
Tumbler switch
0000102286
Reset/start button
0000102289
Relay MC2A
0000102290
Transformer 50W/24V 115/230/400 V
0000102297
Aluminium fan wheel 50Hz
0000102305
Fan housing, motor side
0000102310
Star knob M8
0000102313
Bush Ø 203 mm
0000102344
Membrane + spring of magnetic valve
0046020040
Pressure regulating valve + pressure gauge
0046030010
Pressure relief valve 6-10 bar
0050101210
Hose set extraction arm for mounting on mobile unit
0102080110
Spark arrester (HD)
0328050120
Main switch VCO
0609590110
Starlock 22 mm
0612010220
Adjusting ring 19x1
0708020150
Aluminium fan wheel 60Hz
0805030010
Wheel Ø 250 mm black
0805040010
Swivel castor Ø 125 mm with brake
0805040050
Swivel castor Ø 125 mm without brake
0830301030
Sealing dust tray
0830301050
Sealing
9823020000
Filter cover incl. outlet grid
9824000020
Pressure difference switch (800 Pa)
9824000090
Piston mechanism
9850040090
Wheel covers yellow (2 pieces)
9850060110
DuraFilter FCC-30
9870080160
Fuse 2,0 A (10 pieces)
MFS 400V/3ph/50hz
0000102287
Thermal relay NTR 1.7-2.4A
0320000100
Motor 0,75kW, 230-400V/3ph/50-60Hz
MFS 230V/3ph/50hz
0000102288
Thermal relay NTR 3.0-4.7A
0320000100
Motor 0,75kW, 230-400V/3ph/50-60Hz
0507260010/301113/G MFS - MFS/C
possible
Solution
cause
Main filter
Replace main filter
damaged.
(ref. 6.2.1).
Sealing on main
Replace main filter
filter damaged.
(ref. 6.2.1).
Main filter
Place main filter
placed
correctly.
incorrectly.
Dust tray placed
Position dust tray
incorrectly.
correctly and
tighten star knob.
Sealing material
Replace sealing
of dust tray
material.
defective.
Imbalance in
Clean the extraction
the extraction
fan.
fan.
article no.
Description
MFS 230V/1ph/50hz
0321012030
Motor 0,75kW, 115-230V/1ph/50-60Hz
0328400130
Thermal relay NTR 4.0-6.3A
MFS 115V/1ph/50hz
0321012030
Motor 0,75kW, 115-230V/1ph/50-60 Hz
0328400160
Thermal relay NTR 10-14A
MFS/C 400V/3ph/50hz
0000102287
Thermal relay NTR 1.7-2.4A
0041000040
Compressor unit MFS 230V/1ph
0320000100
Motor 0,75kW, 230-400V/3ph/50-60Hz
MFS/C 230V/3ph/50hz
0000102288
Thermal relay NTR 3.0-4.7A
0041000040
Compressor unit MFS 230V/1ph
0320000100
Motor 0,75kW, 230-400V/3ph/50-60Hz
MFS/C 230V/1ph/50hz
0041000040
Compressor unit MFS 230V/1ph
0321012030
Motor 0,75kW, 115-230V/1ph/50-60Hz
0328400130
Thermal relay NTR 4.0-6.3A
9

ELECTRICaL DIagRaM

Refer to the separately supplied electrical diagram.
10

DISpOSaL

After life of the machine, dispose it of in accordance with
federal, state or local regulations.

CE DECLaRaTION

EC declaration of conformity for machinery
We, Plymovent, Wezelkoog 11, 1822 BL Alkmaar, the
Netherlands, herewith declare, on our own responsibility, that
the products:
- MFS
- MFS/C
which this declaration refers to, are in accordance with the
conditions of the following Directives:
- Machinery Directive 2006/42 EC
- EMC 2004/108 EC
- LVD 2006/95 EC
- ErP Directive 2009/125 EC
Alkmaar, The Netherlands, 30 November 2013
Ir. F. Coehoorn
Vice President Researchh & Development
EN - 10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mfs/c

Table des Matières