Use of the remote transmitter
Detailed description of the basic and advanced features of the IR transmitter depends on
a given type (please see user manual attached to your IR transmitter).
Examples of features of an IR transmitter – type DT-IR1
– control of temperature inside the room (in Local Mode the device controls the
temperature of the radiator)
– possibility to program two temperature settings: Comfort and Economical and easy
switch from one to the other
– automatic temperature adjustment program for Comfort and Economical setting
during a 24hour period (24-hour timer)
– automatic dryer program
– automatic Anti-freeze program with possibility to adjust the operation threshold
– possibility to adjust the temperature sensor according to the specific conditions of
a given interior (calibration feature).
No signal detection (automatic feature):
The transmitter sends a controlling signal every 10 minutes in order to check the quality
of communication between the two devices. Interruption or lack of 3 subsequent signals
(30 minutes) will result in automatic changeover of the KTX 4 controller to the Local
Mode with the "0" setting. The controller will wait for communication to resume (display
panel will show "0" and
icon will start flashing). Having received the controlling signal,
the device will automatically return to remote operation.
PROBLEM SOLVING
Problem
Possible cause
Device is connected to
Connection problem
electricity, LED display
panel is empty
Heating element does not
Device signals emergency,
heat, LED display panel
temperature sensor has
shows E1 or E2 code
been damaged
Controller is incorrectly
installed on the heating
element
Short, single flashes of the
Controller is working
dash on the display panel
properly – flashes indicate
(in remote mode)
receipt of controlling sig-
nal from the IR transmitter
Device automatically
Communication problem:
switched from remote to
sensor is inaccessible or
local mode
the devices have been
incorrectly set against
each other
Heating element is heating
Electronics damage
despite being turned off
with the
button
If the problem persists, please contact your local distributor
Solution
Check the power wire
connection, plug and the
socket
Disconnect the device
completely from electric-
ity, wait for the radiator
to cool down and turn it
back on
Check if the head of the
heating element is com-
pletely hidden. Release
the screw at the back
of the controller casing,
gently push the controller
towards the radiator and
secure the casing back
Remove any objects that
may be disrupting com-
munication between the
two devices or mount the
IR transmitter in
a different location
Disconnect the device
completely from electric-
ity, wait for the radiator
to cool down and turn it
back on