CLOCK PROGRAMMING
Press both arrow buttons at the same time
Hour field will start flashing
Set the required hour using
and
Confirm it by
pressing .
Minute field is flashing
Set the required minutes using
and
pressing .
Set time is displayed.
Clock programming is finished.
In case of electric power supply failure, after the electricity is back on, the display panel
will show the last remembered time. The displayed time may not be correct – this will be
indicated by the Clock sign flashing. Please confirm the time by pressing any button or
program the correct setting.
24-HOUR TIMER
24-hour Timer enables specification of 4 different time zones (T1, T2, T3 and T4), which al-
low different temperature settings and, including periods when the device is switched off.
The start of every time zone is programmed subsequently from T1, T2, T3 to T4 (hour
and minutes), and the temperature for every time zone is specified. The entire cycle is
repeated every day on condition that the device is on and Timer is active.
Turning the device off does not delete the Timer settings.
After turning the device back on with the
clock settings from before the device was turned off.
In order to deactivate the Timer press the
Timer to OF and press
again (the device will switch to the Manual Mode).
During the Timer operation, Dryer Mode can also be used – Dryer Mode command is
superior to the Timer therefore the device will act according to the parameters set for
the Dryer, only after the Dryer Mode is finished will the device go back to the Timer
function (see → Dryer Mode).
confirm it by
button the Timer will be activated with the
, button for a while, use the arrows to set the
TIMER PROGRAMMING
Turn on the device by pressing
.
Press and hold
→ button ON or OF will start flashing
Activate (On) or deactivate (Of) the mode with the use of
and . Confirm by pressing .
Clock field is flashing on the display panel and T1 is on
Set the START of the first time zone with the use of
. Confirm by pressing .
et the START of subsequent time zones T2 – T4 with the
use of
and
. Confirm by pressing .
Temperature field is flashing on the display panel and
T1 is on
Set the required TEMPERATURE for T1 zone using
. Confirm by pressing .
Set the required TEMPERATURES for the time zones
T2 – T4.
Confirm by pressing .
Display panel is no longer flashing, TIMER icon and a
relevant time zone code T(1-4) depending on current
time are on
TIMER programming is finished.
Attention: When TIMER is active and it controls the device functions, the user may
modify the set temperature without influence on the current program. The manual set-
ting will only operate until the next automatic TIMER setting change.
and
and