Operation

Connection

Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications.

Autostart

Connect the power tool to the electrical outlet on the machine. Set the switch to AUTO. The machine will then automatically start
when the tool is used. The machine turns off a few seconds after the connected tool is powered down. To manually start the ex-
tractor, set the switch to MAN.

Filter cleaning:

The machine has a filter status indicator that lights up when the filter needs to be cleaned or replaced. The filters must be cleaned
1-2 times a day with continuous use and when the manometer needle is in the red field.
The filters should be cleaned when the manometer is in the red field.
Cleaning the filter:
During filter cleaning, the machine should be running and the hose removed from the suction pipe.
1. Press the connector sleeve against the black stop lug on the exhaust duct or against the floor in order to produce maximum
negative pressure in the cyclone.
Open and close the hatch on the side 3-6 times. Air flows into the machine and cleans the filter by creating a reverse pulse.
2. Turn off the machine and let the material fall down. Reconnect the suction pipe.
3. Start the machine.
4. If the manometer needle is back in the green zone, work can continue. If it remains in the red zone, the cleaning process
should be repeated. Some actions (such as those that restrict air flow) may cause the manometer to display a high value
(needle in the red zone). The machine should never be left on continuously when the meter is in the red zone, as there is a
risk of overheating. The transition from the green zone to the red zone takes place at 18 kPa.