Alternating current (A/AC)
Range
400.0 µA
4000 µA
40.00 mA
400.0 mA
4.000 A
10.00 A
600 V overload protection
Fuses: µA/mA = 3x 160 mA resettable PTC fuses
10 A = High-performance FF12AH1000V ceramic fuse
≤ 6 A = continuous measurement, >6A = max. 10 secs at intervals of 15 minutes
The multimeter may display 3 counts when a measuring input is open
TrueRMS peak (Crest Factor (CF)) ≤3 CF over the entire range
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 - 2.0
+ 3%
CF >2.0 - 2.5
+ 5%
CF >2.5 - 3.0
+ 7%
Resistance
Range
400.0 Ω*
4.000 kΩ*
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
600 V overload protection
Measuring voltage: Approx. 1.0 V, measuring current approx. 0.7 mA
*Accuracy for measuring range ≤ 400 Ω was calculated after deducting lead resistance from the REL function
64
Resolution
0.1 µA
1 µA
0.01 mA
0.1 mA
0.01 A
0.01 A
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy
±(1.3% + 6)
±(1.6% + 4)
±(2.0% + 7)
Accuracy
±(1.3% + 3)
±(1.2% + 6)
±(1.6% + 4)
±(3.0% + 6)