5 - CONTINUITY AND RESISTANCES

Always check the battery condition before
using your multitester.
Never measure a resistance on a live circuit.
Connect to the terminals of the component or
the circuit to be tested.
Proceed as for a voltage measurement to
check that there is no voltage present.
Press the push button on the back of the ins-
trument : the display sets to the 2kW range.
Read the measured value.
NB : A beep is emitted for any resistance
£ 500 W ± 50 W ; this is the continuity sound
test
Release the press button and disconnect the
multitester from the circuit: it switches OFF
automatically.
SPECIAL FUNCTIONS OF THE CDA 104
Memory : see Description (HOLD)
Backlighting of the display :
see Description (
Presence of voltage (Volt-test) :
If the circuit is accidentally switched on during
measurement of resistances, the red W light
comes on. Release the ohmmeter button
immediately; the CDA 104 displays the value
of the voltage present.
voltage
W W W W W
on open on open lution
circuit
(1)
2 kW
400 mV
(1)
Beep for a resistance R £ 500 W ± 50 W .
NB : for a resistance R > 1.999 kW , "1"
flashes.
(2) 5 seconds max.
Max
Max
current
circuit
150 µA
).
Reso- Accu-
1 W
1 6
Protec-
racy
tion
± 3% 600V rms.
± 2pt
(2)