General Specifications - Chauvin Arnoux CDA 103 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6 - GENERAL SPECIFICATIONS

6.1 POWER SUPPLY
2 batteries 1.5V (type R6 or LR6)
Service life (with R6 batteries) :
10,000 measurements of 10 seconds for the
CDA 104
20,000 measurements of 10 seconds for the
CDA 103
NB : The service life is doubled with LR6
alkaline batteries.
Consumption :
< 5mA on voltmeter
< 20mA on ohmmeter with beep
< 50mA with backlighting, on the CDA 104
6.2 DIMENSIONS AND WEIGHT
170 x 65 x 30 mm - 200 g with batteries
6.3 REFERENCE CONDITIONS
Temperature : +23°C ± 3°C
Relative humidity : 45 to 55 % RH
Frequency : 45 to 65 Hz
6.4 CLIMATIC CONDITIONS
Operation : -10°C to +55°C
Storage :
6.5 CONFORMITY WITH INTERNATIONAL
STANDARDS
Double insulation
voltage of 600V rms, installation category III,
degree of pollution 2)
Watertightness (to IEC 529) : IP 40
10% RH to 90% RH
-40°C to +70°C
5% RH to 95% RH
(to IEC 1010.1, service
1 7

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cda 104

Table des Matières