Auto OFF
Once it is disconnected from the circuit, the
multitester switches OFF automatically; the
display goes blank.
Live/neutral identification
Because of its great sensitivity, the multitester
detects live and neutral in a power point.
- Socket without earth. Insert the positive prod
(red) into the socket ; with the black prod in
the air. If the display lights it is live. If the
display remains unlit, it is the neutral.
- Socket with earth. By connecting the black
prod to the earth, and the other one to the
live or the neutral, the earth/live or earth/
neutral voltage is measured, without setting
off RCD's (consumption 1.4 mA at 380 V).
SPECIAL FUNCTIONS ON THE CDA 104
Hold: see Description (HOLD)
Backlighting of the display :
see Description (
Additional 200mV DC range (Z = 1 MW )
It is possible to temporarily go below the mini-
mum voltage threshold of 600mV on DC. With
the CDA 104 disconnected from all circuits,
proceed as follows.
Press simultaneously the HOLD button and
the ohmmeter button ; the multitester sets to
DC voltage for approx 20 seconds :
- 200 mV DC range (0 to 199.9 mV)
- 2 V DC range (0.200 V to 1.999 V)
V DC and AC
Resolution
Impedance
Accuracy
Permissible
overload
(1) Operating range : 10 Hz to 400 Hz sine.
(2) Display 2000 counts limited to 600V rms.
(3) Accuracy as a % of the reading.
2 V
(1)
1 mV
600 kW
(3)
).
20 V
10 mV 100 mV
± 2 % ± 2 cts on DC and
± 3 % ± 5 cts on AC
1000 V rms for 5 seconds
15
200 V 600 V
260 kW
(2)
1 V