13. For positioning of temperature sensor holder on wall (see
Figure 15). Choose position 1 if possible. Position 2 will
reduce the sauna temperature.
Install the temperature sensor holders (see (1) in Figure 16)
400 mm below the ceiling and 145 mm between using the
two supplied screws (4).
NB: Take care not to damage the capillary tube,
which contains liquid. Do not splice! Do not split!
Insert the temperature sensor (located on the side of the
heater, see Figure 18) and attach the cover profiles. Secure
the capillary tube with the clips (2) and the brad nail (3) (see
Figure 16).
The sensor could either be installed vertical or horizontal,
(see figure 17)
2
2
1
Figure 15: Positioning of temperature sensor
400 mm
1
2
3
Figure 16: Installing the temperature sensor
1
5
Figure 17: Temperature sensor placement
Figure 18: Finding the temperature sensor
4
13