ERRORS AND FAULTS IN USE
If the motorcycle power supply is abnormally disconnected during use, refer to the
following elements :
1.
BATTERY PROTECTION
The system has several safety features.
In general, the battery is automatically reset.
If this is not the case, be sure to remove it from the bike and then reinstall it.
2.
BATTERY EMPTY SAFETY
The battery has an automatic shutdown if the voltage drops below 45V when loaded
(riding). The battery charge cancels this condition.
3.
INSTANTANEOUS OVERCURRENT PROTECTION
The battery has an automatic shutdown if the current exceeds 250A.
To reset, switch off and then switch on the battery from the led panel.
4. CONTINUOUS OVERCURRENT
In order to prevent the battery from overheating, the battery is protected if the current
output exceeds 85A for 10 seconds.
The battery then cuts off the power supply.
To reset, switch off and then switch on the battery from the led panel.
5.
EXCESSIVE TEMPERATURE
The battery has 4 temperature sensors
If the temperature exceeds 75 ° C, the power turns off. When the temperature drops
below 65 ° C, the battery resets and the motorcycle restarts.
A battery temperature> 65 ° C prohibits charging the battery.