Codice /
Dip switch ON
Code
223
1,2,3,4,5,7,8
Comando serratura su SE in AC (default)
224
6,7,8
Comando serratura su SE in AC potenziata
225
1,6,7,8
Tempo serratura: 2 sec + tono disattivo
245
1,3,5,6,7,8
246
2,3,5,6,7,8
247
1,2,3,5,6,7,8
248
4,5,6,7,8
251
1,2,4,5,6,7,8
Relè C.NC.NO in parallelo a SE (default)
252
3,4,5,6,7,8
253
1,3,4,5,6,7,8
Apriporta attivo solo per utente chiamato
N.B. sull'impianto non deve essere presen-
te l'Art. 1256 in modalità attuatore generico.
Attivazione relè C.NC.NO su comando
229
1,3,6,7,8
Attivazione relè C.NC.NO su comando
230
2,3,6,7,8
Attivazione relè C.NC.NO su comando
231
1,2,3,6,7,8
Comando attuatore su linea seriale S:
228
3,6,7,8
227
1,2,6,7,8
Comando attuatore su linea seriale S: attivo
232
4,6,7,8
Tempo di attesa risposta: 60 sec (default)
233
1,4,6,7,8
Tempo di attesa risposta: 120 sec
234
2,4,6,7,8
235
1,2,4,6,7,8
Tempo di conversazione: 90 sec (default)
236
3,4,6,7,8
Tempo di conversazione: 180 sec
237
1,3,4,6,7,8
238
2,3,4,6,7,8
Tono conferma su chiamata utente:
239
1,2,3,4,6,7,8
240
5,6,7,8
Tono conferma su chiamata utente: disattivo
243
1,2,5,6,7,8
Tempo di attesa reset: 10 sec (default)
244
3,5,6,7,8
208
5,7,8
Reset dopo apriporta in fonica: attivo (default)
209
1,5,7,8
Reset dopo apriporta in fonica: disattivo
249
1,4,5,6,7,8
250
2,4,5,6,7,8
Gestione posti interni collegati all'Art. 1622:
241
1,5,6,7,8
Gestione posti interni collegati all'Art. 1622:
242
2,5,6,7,8
000
255
1,2,3,4,5,6,7,8
254
2,3,4,5,6,7,8
Serratura
Comando serratura su SE in DC
(default)
Tempo serratura: 4 sec
Tempo serratura: 8 sec
Tono conferma serratura: attivo
Apriporta sempre attivo (default)
Gestione comando attuatore
attuatore: 2 sec
attuatore: 4 sec
attuatore: 8 sec
disattivo (default)
Funzioni impianto
Tempo di attesa risposta: 30 sec
Autoaccensione: attiva (default)
Autoaccensione: disattiva
attivo (default)
Tempo di attesa reset: 1 sec
Invio chiamata: singola (default)
Invio chiamata: tripla
fino a 70 (default)
da 71 a 100
Modalità impianto
Simplebus (default)
Simplebus Top
Ripristino default
Door lock
Door lock command on SE in AC (default)
Door lock command on SE in enhanced AC
Door lock command on SE in DC
Door lock time: 2 sec + deactivation tone
(default)
Door lock time: 4 sec
Door lock time: 8 sec
Door lock confirmation tone: enabled
C.NC.NO relay in parallel with SE (default)
Lock-release always enabled (default)
Lock-release only enabled for user called
Actuator control management
N.B. the system should not include Art.
1256 in generic actuator mode.
Enabling C.NC.NO relay on actuator control:
2 sec
Enabling C.NC.NO relay on actuator control:
4 sec
Enabling C.NC.NO relay on actuator control:
8 sec
Actuator control on serial line S:
disabled (default)
Actuator control on serial line S: enabled
System functions
Awaiting response time: 60 sec (default)
Awaiting response time: 120 sec
Awaiting response time: 30 sec
Talk time: 90 sec (default)
Talk time: 180 sec
Self-ignition: enabled (default)
Self-ignition: disabled
Confirmation tone on user call: enabled
(default)
Confirmation tone on user call: disabled
Reset wait time: 10 sec (default)
Reset wait time: 1 sec
Reset after lock-release in audio:
enabled (default)
Reset after lock-release in audio: disabled
Call transmission: single (default)
Call transmission: triple
Control of internal units connected to Art.
1622: up to 70 (default)
Control of internal units connected to Art.
1622: from 71 to 100
System mode
Simplebus (default)
Simplebus Top
Restore default
Gâche
Commande gâche sur SE en CA (par défaut)
Commande gâche sur SE en CA intensifié
Commande gâche sur SE en CC
Temps gâche : 2 sec + tonalité désactivée
(par défaut)
Temps gâche : 4 sec
Temps gâche : 8 sec
Tonalité confirmation gâche : active
Relais C.NC.NO en parallèle à SE (par défaut)
Ouvre-porte toujours actif (par défaut)
Ouvre-porte actif uniquement
pour usager appelé
Gestion commande actionneur
N.B. l'Art. 1256 en modalité actionneur
générique ne doit pas être présent dans
l'installation.
Activation relais C.NC.NO sur commande
actionneur : 2 sec
Activation relais C.NC.NO sur commande
actionneur : 4 sec
Activation relais C.NC.NO sur commande
actionneur : 8 sec
Commande actionneur sur ligne série S :
désactivée (par défaut)
Commande actionneur sur ligne série S : active
Fonctions installation
Temps d'attente réponse : 60 sec (par défaut)
Temps d'attente réponse : 120 sec
Temps d'attente réponse : 30 sec
Temps de conversation : 90 sec (par défaut)
Temps de conversation : 180 sec
Auto-allumage : actif (par défaut)
Auto-allumage : désactivé
Tonalité confirmation sur appel usager :
activée (par défaut)
Tonalité confirmation sur appel usager :
désactivée
Temps d'attente reset : 10 sec (par défaut)
Temps d'attente reset : 1 sec
Reset après ouverture gâche en phonie :
actif (default)
Reset après ouverture gâche en phonie :
non actif
Envoi appel : simple (par défaut)
Envoi appel : triple
Gestion postes intérieurs reliés à l'Art. 1622 :
jusqu'à 70 (par défaut)
Gestion postes intérieurs reliés à l'Art. 1622 :
de 71 à 100
Modalité installation
Simplebus (par défaut)
Simplebus Top
Rétablissement réglage d'usine
11