3.2 - DOUBLE OUTLET INSTALLATION DRAFT
Suction
1
Compression
With this system, a check valve (1) must be fitted on the delivery tube to prevent the transfer of sewage inside
the Rotary blades vacuum pump.
3.3 - ASSEMBLY AND MOUNTING - INSTALLATION
The Rotary blades vacuum pump should be assembled and installed using the following procedure:
1) Assemble the Rotary blades vacuum pump in horizontally with its feet facing downwards. The assembly position on the vehicle
should be easy to access and protected. It is necessary to foresee enough space for suction and delivery hoses. A 5° maximum
longitudinal slope of the Rotary blades vacuum pump with respect to the horizontal plane must not be exceeded.
2) Bolt the Rotary blades vacuum pump using screws and nuts passing through the specially provided slots or holes in the feet;
3-M) To install .../M- version, connect the tractor's cardan shaft at 540 rpm to the Rotary blades vacuum pump power take-off shaft.
Don't exceed the maximum slope allowed for the cardan shaft
3-MA-KA) To install the Rotary blades vacuum pump MA-KA version, connect the tractor's cardan shaft at 1000 rpm to the Rotary
blades vacuum pump power take-off shaft.
Don't exceed the maximum slope allowed for the cardan shaft
3-D) To install the Rotary blades vacuum pump .../ D version, connect the tractor's cardan shaft at 1000 rpm to the Rotary blades
vacuum pump power take-off shaft.
Don't exceed the maximum slope allowed for the cardan shaft
3-H) To install the Rotary blades vacuum pump H-HFR version, fit a hydraulic motor (fringing SAE/C 4 holes – ANSI 127-4 or
SAE/C 2 holes – ANSI 127-4 for KTS and KTM series, for WPT series European flange) on the power take-off shaft and fastening
it, using special screws, to the support located at the front part.
3-P) To install the Rotary blades vacuum pump .../P version, attach a driven pulley to the power take-off shaft and fasten it with
for WPT, KTS, KPS, KTM, WSM series use and maintenance
The Rotary blades vacuum pump can be used
as a mixer by fitting, on request, a double
outlet on the manifold (see Figure 2). In this
case there will be a normal Rotary blades
vacuum pump for the intake but a perforated
tube must be placed inside the tank-cart
for the compression. When the handle is
positioned on the compression phase, the air
will be forced out through the holes in the
tube so causing a mixing of the previously
loaded sewage. (Never exceed the maximum
working absolute pressure of 2,5 bar) equal to
1,5 relative bar.
Figure 2
Instruction Manual
pag. 41