● When istalling metal connectors, always
place the exposed point of the metal
connector nail into the metal connector's
pre-formed hole, and orient so the nail is
perpendicular to the hole before attempting
to drive a fastener.
NOTE
● THIS is a SEQUENTIAL TRIP MECHANISM, and
should be used in accordance with all warnings and
instructions.
● Always handle nails and package carefully. If nails
are dropped, collating paper may be broken.
● After nailing:
1) disconnect air hose from the Nailer;
2) remove all nails from the Nailer;
3) supply 5 – 10 drops of metabo HPT pneumatic
tool lubricant into the air plug on the Nailer; and
4) open the petcock on the air compressor tank to
drain any moisture.

CHANGING THE EXHAUST DIRECTION

● When changing the exhaust direction, be
sure to remove your fi nger from the trigger
and disconnect the air hose from the nailer.
The direction of the exhaust vent can be changed by
turning the top cover.
Exhaust
Vent
WARNING
Top Cover