Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
Efficiency, fine filter, EN 60335-2-69, Class H [%]
Filter classification, EN 1822-1
Sound level [dB(A)]
*/ Sound pressure level at 1.6 m height and 1 m distance according to DIN EN ISO 3744 in free field measurement at maximum
air flow.

Operation

Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications. If using an extension
cord, it must be water-resistant. Check the direction of rotation of the motor. For machines with a phase converter, the direction of
rotation can be changed easily. For other machines, an electrician must change the phase sequence.
Filter cleaning
The filters should be cleaned when the manometer is in the red field.
1.
Keep the machine switched on and close the throttle at the cyclone inlet. Reset the filter cleaner button.
2.
Wait for 5-10 pulses.
3.
Switch off the machine.
4.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
5.
Switch on the machine.
6.
Check that the pressure gauge indicates green or that the filter indication lamp is off. If not, repeat the procedure. If the
gauge indicates red or the light is on even after repetition, the fine filter needs to be replaced. If it, despite the filter change,
still indicates red, the vacuum valve must be checked.
18
DC Storm 500 c/a/L
HEPA H13
99,995
75
DC Storm, Art.nr.94295-C
DC Storm 700 c/a/L
HEPA H13
99,995
75

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dc storm 700

Table des Matières