DIAGRAM OF ELECTRICAL CONNECTIONS TO PERIPHERALS
To connect the accessories and peripherals to the pump remove the front cover "1", using a flat-tip screwdriver on the
two plastic screws, to access the terminal board (see Figure 9).
The "3" terminal board features spring terminals (there are no screws) for quick connection of the cables: press with a
small screwdriver at the "carved" square pin and insert the conductor previously stripped in the corresponding terminal.
N° Terminal
1
2
3
4
5
6
7
8
9
10
11
Description
mA (-) Input
mA (+) Input
Meter Input (-)
Meter Input (+)
Level Input (-)
Level Input (+)
Flow Switch Input (-)
Flow Switch Input (+)
Not Connected
Not Connected
Not Connected
Fig. 9 – Terminal Board
N°
Terminal
12
Not Connected
13
Not Connected
14
Not Connected
15
Not Connected
16
Not Connected
17
Not Connected
18
Not Connected
19
Alarm Relay (NO)
20
Alarm Relay (NC)
21
Alarm Relay (COM)
Description
ENGLISH 67