x 2
add. start
hidden butt
Add. 2ch
hidden butt
erase 64
language
autoset
Control unit
software version
stat
OK
vers
bft . . .
+/-
- +
No total
manoeuvres(in hundreds)
OK
0000
n. cycles
+/-
- +
No radio control
devices memorised
n. remotes
OK
00
+/-
- +
List of last 30 errors
01.33
OK
err
02.01
........
30.15
+/-
0---
password
ACCESS MENUS Fig. C1
INSTALLATION MANUAL
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
See RADIO MENU
DIAGNOSTICS
CODE
STOP input activated
stop
Open-key input activated
ey
INTERNAL RADAR input activated
intr
EXTERNAL RADAR input activated
extr
OPENING SAFETY DEVICE input activated
opph
CLOSING SAFETY DEVICE input activated
clph
OPENING SAFETY DEVICE WITH
OPDZ
"DETECTION ZONE" input activated
Multifunction input activation
ltf, d - n -
Error in safety device test during opening
Er03
Error in safety device test during closing
Er04
Encoder disconnected or faulty
Er21
Encoder wrong way round with respect to motor
Er22
rotation
Communication error with operation board for
ER50
operation with "ELA SL 24.B KIT "
Error in communication between automatic doors
Er52
in cage mode.
Error in communication with devices connected to
Er53
RS485 serial line.
Board hardware test error
ER1x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters
ER72
(Logics and Parameters)
D-track parameter error
ER73
solenoid lock output overload
erf9
autoset function is running. WARNING! Obstacle
SET
detection function is not active
*X= 0, 1, .., 9, A, B, C, D, E, F
150-
10--
Fig. C2
Opening
G
A
B
C
E
DESCRIPTION
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
Check for obstacles in path
Allow automated device to cool
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-
track as a default.
An autoset is required
check solenoid lock connections
1520
prg
Closing
H
B
A
F
D
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
NOTES
- 39
VISTA-SL C (ARIA-EVO)