LOGIC
DEFINITION
Setting the
prot. lev
protection level
Serial mode (Identifies how
SERIAL
board is configured in a BFT
MODE
network connection).
Address
ADDRESS
Automatic door
operating mode
door
ode
(LOGIC 72)*
Activation radar ON
radar
(LOGIC 73)*
setup
Buzzer operating mode
buzzer
(LOGIC 74)*
"Cage" mode operating mode
revolving
(LOGIC 75)*
* Refer for universal handheld programmer.
38
- VISTA-SL C (ARIA-EVO)
INSTALLATION MANUAL
Cross out
DEFAULT
using
setting
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has
already been memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be
memorized.
0
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be
added to the receiver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
0
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions
D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also
stops radio interference, if any.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
0
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED,
1
STOP) to other boards.
Identifies board address from 0 to 119 in a local BFT network connection.
[ ___ ]
0
(see SCS OPTIONAL MODULES section U-LINK)"
0
1
2
3
0
Door mode []. Sets the door's operating mode (Sect. DOOR OPERATION MODE)
4
5
6
7
8
0
0
Radar mode []. Sets the radars' operating mode (Sect. RADAR OPERATION MODE)
1
2
0
1
0
Buzzer mode []. Sets the buzzer's operating mode (Sect. RADAR OPERATION MODE)
2
3
4
0 Single door mode
0
Internal/External door (Sect. CONNECTING 2 DOORS IN cage MODE)
0
1
2 Door set as EXTERNAL in "Revolving" mode.
1 Door set as INTERNAL in "Revolving" mode.
2
DESCRIPTION