5.3 Scope of delivery
Pump with
• 10 metre connecting cable with mains plug
• Connected float switch (design-A)
• Turbulator (TSW)
• Hose connection (Ø 32 mm / R 1)
• Non-return valve
• Installation and operating instructions
5.4 Accessories
Accessories must be ordered separately (see cat-
alogue):
• Switchgear for 1 or 2 pump operation
• External monitoring devices / tripping unit
• Level control (e.g. flow switch)
• Accessories for transportable wet sump installa-
tion (e.g. hose couplings, hoses, etc.).
• Accessories for stationary wet sump installation
(e.g. check valves, non-return valves, etc.)
6 Description and function
6.1 Description of the product (Fig. 1)
Pos. Description of the
component
1
Cable and float switch 16
2
Clip for float switch
3
Cap nut
4
Housing
5
Motor cover, top
6
Screw
7
Motor housing
8
Rotary shaft seal
9
Circlip
10
Washer
11
Mechanical seal
12
Seal
13
O-ring
14
Seal housing
15
Screw
The pump can be completely submerged in the
fluid.
The submersible pump housing consists of stain-
less steel.
The electric motor is protected against the pump
chamber by a rotary shaft seal to seal the motor
against the oil chamber and a mechanical seal to
seal the oil chamber against the fluid. The
mechanical seal chamber is filled with medical
white oil so that the mechanical seal is lubricated
and cooled during a dry run. A further rotary shaft
seal protects the mechanical seal facing the fluid.
The motor is cooled by the surrounding fluid.
The pump is installed on the floor of a shaft. For a
stationary installation, it is bolted to a fixed pres-
sure pipe or for a transportable installation, it is
Installation and operating instructions Wilo-Drain TS/TSW
Pos. Description of the
component
Rotary shaft seal
17
O-ring
18
Supporting ring
19
Screw
20
Pump housing
21
Impeller
22
Washer
23
Cap nut
24
Strainer
25
Screw
26
Hose connector
Ø 32 mm / R 1
(not illustrated)
27
Non-return valve
(not illustrated)
28
Guide plate
29
Turbulator
connected to a hose connection.
The pumps are commissioned by plugging in the
protective contact plug.
They operate automatically, when the float switch
switches the pump on from a certain water level
"h" (Fig. 2) and switches it off at a minimum water
level "h1".
The motors are equipped with thermal motor pro-
tection, which switches off the motor automati-
cally if it overheats and switches it on again when
it has cooled down. The condenser is integrated in
the single-phase motor.
Version TSW with turbulator
For waste water with precipitating and floating
particles, the submersible pump has been
equipped with a turbulator at the suction strainer.
Precipitating particles are continuously whirled up
in the suction area of the pump and pumped off
with the water. Therefore, mud accumulation in
the pump shaft, with problematic consequences
such as clogging of the pump and odour forma-
tion, is largely prevented.
If the removal of the waste water does not allow
any interruption, a second pump (automatic
standby pump), together with the necessary
switchgear (accessory), increases the operating
reliability if the 1st pump develops a fault.
English
13