TECHNICAL DATA
THERMO-TECHNICAL CHARACTERISTICS pursuant to EN 303-5 with pellets A1 according to EN 14961-2
Power to firebox
Power to water
Yield
CO emission at 10% O
2
Smoke temperature
Fuel consumption
Tank capacity
Draft
Water content
Max water operating pressure
Max H
O operating temperature
2
Water side load loss
Autonomy
Heatable volume *
Ø smoke pipe (male)
Ø air intake pipe (male)
Weight with packaging
TECHNICAL DATA FOR CHIMNEY FLUE DIMENSIONING which must however comply with the instructions in the
data sheet and the installation standards of each product
Power to firebox
Smoke outlet temperature on dis-
charge
Minimum draught
Smoke capacity
* The heatable volume is calculated considering home insulation pursuant to L 10/91 and subsequent amendments
and a heating requirement of 33 Kcal/m³ per hour.
* It is important to also take into consideration the location of the boiler in the environment to heat.
(1)
The technical data can vary due to use of fuel with different characteristics.
ELECTRICAL CHARACTERISTICS
Power supply
Average absorbed power
Absorbed power when switching on
Protection on electronic board
N.B.
1) take into consideration that external equipment can disturb functioning of the electronic board.
2) attention: intervention on powered parts, maintenance and/or checks must be carried out by qualified staff (Before
carrying out any maintenance, disconnect the appliance from the electrical power mains).
3) In the event of electrical problems, consult the electrician to assess the installation of an uninterruptable power sup-
ply unit at least 800 VA with sine waves. Variation over 10% of power can cause problems with the product.
The data outlined above are approximate and relate to the certification phase carried out by the notified body.
EDILKAMIN s.p.a. reserves the right to change the products without prior notification at its discretion.
GENERAL INFORMATION
LAGUNA M 25
Nominal power
Reduced power
24.2
21.9
90
0,016
139
5.1
70
0.12 - 0.03
54
2
90
200 a ΔT = 20 K - 750 at ΔT = 10 K
13
570
100
60
260
LAGUNA M 25
Nominal power
Reduced power
24.2
167
0 - 0.05
14.2
- 52
LAGUNA M 33
Nominal power
7.1
32
6.4
29.1
89.5
91
0,014
0,025
70
154
1.5
6.7
200 a ΔT = 20 K - 750 at ΔT = 10 K
45
10
LAGUNA M 33
Nominal power
7.1
32
83
184
8.1
17.4
230Vac +/- 10% 50 Hz
115 W (Laguna M 25) -129 W (Laguna M 33)
300 W
Fuse T6,3A, 250 Vac 5x20
-
Reduced power
9.5
8.7
91.4
0,013
74
2
70
0.12 - 0.03
54
Litres
2
90
34
hours
760
100
60
270
Reduced power
9.5
89
0 - 0.05
10
(1)
kW
kW
%
%
°C
kg/h
kg
mbar
bar
°C
mbar
m
3
mm
mm
kg
kW
°C
mbar
g/s