Examples:
· Panel configured as Block
Block 25, range of telephones 25XXXX.
· Panel configured as Block + Sub-block
Block 12 / Sub-block 03, range of telephones 1203XX.
· Panel configured as General Entrance
General Entrance, range of telephones XXXXXX (000001 to 999999).
Upon making a call,
· If a Panel is configured as Block it only allows the call to the configured Block (BB).
Block 25, if pressing1 +  the following calling code is generated 250001.
· If a Panel is configured as Block+Sub-block it only allows the call to the configured Block
(BB) and Sub-block (SS).
Block 12 / Sub-block 03, when pressing
120301.
· If the Panel is configured as General Entrance
If you
press1
+  you generate the calling code
Upon making a call, if the selected terminal is in the installation and available (it may be in
conversation with another outdoor panel) it is monitored via a characteristic calling one. If
the marked terminal is not available, a call error tone sounds (beep-bop).
NOTES:
-If a shorter code is entered, it is filled in with "0" to the left.
- Use the 'A' key to delete the entered sequence.
- The '0' entered on the left are considered.
- Once the call to a residence is made, and it is proven to exist and not busy, if you press the
again a new call is made to the same home. After 30" the last home marked is not memorised.
Opening the door with a code.
You can enable a lock-release code for all residents. This is a 4 digit code and can be
entered by pressing A when the panel is in stand-by and then the 4 digits.
Opening code: A + XXXX
NOTES:
-This option is deactivated by default. To deactivate the opening code you must enter the value AAAA
in position 08, see "Outdoor panel configuration" on the following page.
- If you press the A key before entering the fourth digit of the opening code, the operation is cancelled.
An error tone (beep-bop) indicates that the access code has been cancelled.
- The open-door relay activation time is the same as when opening from the home.
1
+  generates the following calling code
000001.