Faultfinding; General Information; The Machine Will Not Start - Husqvarna HTC 270 EG Manuel De L'opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Faultfinding

6
Faultfinding
6.1

General Information

This chapter describes all the faults that may occur and how to deal with them. If the
fault cannot be dealt with, or if there are other faults, contact your nearest retailer. See
Contact Information at the front of the manual.
6.2

The machine will not start

Check the machine is connected to the mains supply.
Check the correct voltage is being supplied to the machine.
Check if the emergency stop switch on the control panel is pressed. Reset the
switch by turning it 45°.
Check to see whether the converter is in a fault condition and, if so, remedy this
as follows:
-
Reset the electronics by turning the Grinding knob to "Reset". If this does not
help, reset the frequency converter according to the instructions in chapter
Electronic error codes, page 36.
-
Check the error code in the converter, see the error code table in
chapterElectronic error codes, page 36.
Check the fuses in the control cabinet.
Check that the connector is correctly connected on the underneath of the control
cabinet.
Specifically for HTC 270 EG 1.5kW 110V, one must check the control voltage fuse on
the top of the control cabinet. Push the reset fuse.
34
HTC 270 EG
2.0

Publicité

Table des Matières
loading

Table des Matières