Device sizes 8 and 9
Fig.5-2
Tip!
The barrier between mains input and power terminals can be dismounted to
have more free space for wiring.
Motor
Terminal X105
Connection with ring
cable lug for M10
Terminal data
Device size 8:
E94ASxE1724
E94ASxE2024
Device size 9:
E94ASxE2454
E94ASxE2924
E94ASxE3664
EDK94SH366 DE/EN/FR/ES/IT 3.1
Arrangement of the power connections
Marking
U
V
W
SSP94KL801
Max. conductor cross-section
2
[mm
]
2 x 240
2 x 500 mcm
Wiring the device
Description
Connection of the motor phases
Connection for the PE conductor on the motor side
Tightening torque
[AWG]
[Nm]
19
Power terminals
SSP94KL801
Screw drive
[lb-in]
168
WAF 16
5
91