NSS Part
Number
4491061
3390361
6491931
2691501
NOTE: Crown and Trojan AGM batteries should be charged with the GEL setting.
**The charger has been tested on batteries from the following manufacturers:
Trojan flooded cell
US Battery flooded cell
Deka flooded cell
Crown gel
Concord gel
Discover AGM
Notes on LED indications per DoE compliance:
When first connected to DC (AC not connected), the LEDs will display one or more of the following:
 The LEDs will flash the charger's ID code (this is for PCS internal use only). Once the LEDs flash the ID, they will only display
one yellow LED. This configuration will remain until AC is detected and a charge cycle is in progress.
 There is also a possibility the LEDs will not flash their ID code and only show a yellow LED.
 Lastly, the LEDs may not flash their ID code and may not show any LEDs until AC is detected.
If the AC line and neutral wires are reversed, the unit will wait 2 minutes before starting a charge. NOTE: The 2-minute wait
period will also be a factor if the charger is being powered by anything other than normal grid AC such as a conventional
generator, inverter, etc.
If the AC plug is disconnected during charge, the unit will turn off as expected. The user may hear some clicking noise, but
should not be alarmed. This is the Powered by Battery/DOE functionality checking for AC connection.
TABLE 1 BATTERY TYPES
Crown Part
Battery Volts System Volts
Number
1-1470
12
1-1435
6
1-1437
6
1-1450
6
Amp Hour
36
215
24 & 36
235
24 & 36
200
36
350
Battery Type
Setting
Flooded/AGM
Flooded/AGM
GEL
Flooded/AGM

Publicité