6.2 Conducting the water away using a hose
The water tank can be reconfigured so as to allow the
water to be conducted away into a drain or a large
external tank via a hose. The tank has a connecting
tube on the left frontal side. There is a plug on the end
of the neck of the tube. Pull out the plug and put it in
the small round drain opening on top of the tank. A
normal or common hose (approx. 12mm in diameter)
can be fitted to the connecting tube.
When using a hose, please ensure that the water can
drain off by creating a gradient for the water to flow
away.
6.3 Using a condensate pump
See section 8.2
Please observe the instructions for using a conden-
sate pump as laid down in the operating manual when
a employing a condensate pump.
07. care anD maIntenance
Regular preventative maintenance and observation of
certain prerequisites will guarantee fault-free opera-
tion and a long service life.
After every period of prolonged operation, and at least
once per year, the apparatus should be checked and
thoroughly cleaned.
All moving parts have been treated with low-mainte-
nance permanent lubrication. The entire refrigeration
system is a maintenance-free hermetically-sealed
system and may only be maintained by authorised
specialist companies.
the mains plug must be removed from the
mains socket before any work is carried out on
the apparatus!
• K eep the apparatus free from dust or other deposits.
• O nly use a dry or damp cloth to clean the apparatus.
Do not use running water.
B - 6
• Do not use cleaning agents that are caustic or contain
solvents and only use appropriate cleaning agents
even in the case of heavy soiling.
• Check t he a ir i ntake fi lter r egularly f or f ouling. I t s hould
be cleaned or replaced as necessary.
work on the refrigeration system and the elec-
trical equipment may only be carried out by an
authorised & qualified company!
Cleaning the condenser and evaporator:
This work requires the apparatus housing to be
opened, and therefore may only be carried out by au-
thorised & qualified companies!
• Clean the condenser and the evaporator either by
blowing or sucking them through, or by using a soft
brush. Do not use running water.
• Please note that the fins can easily be damaged
or bent.
• Carefully clean the inside surfaces of the apparatus,
the condensate pan with hose connection, the venti-
lator and the ventilator housing.
• Reinstall all dismounted parts correctly
• Check that the apparatus is functioning correctly
and carry out an electrical safety examination. Im-
portant recycling information! The apparatus uses
the environmentally-friendly and ozoneneutral ref-
rigerant. In accordance with legal stipulati-
ons, or those that apply locally, the refrigerant/oil
mixture used in the apparatus must be disposed of
correctly.