The apparatus has an operating console for function
control. The automatic control, the condensate con-
tainer with integrated overflow protection and the
connection piece for direct extraction of condensate
permit fault-free continuous operation. The appara-
tus conforms with the fundamental health & safety
requirements of the applicable EU legislation.
Application locations for the apparatus:
The apparatus is used wherever dry rooms are re-
quired and wherever subsequent economical damage
(e. g. due to mould formation) is to be avoided.
The apparatus is predominantly used to dry and
dehumidify:
• Living, sleeping, shower or cellar rooms
• Laundries, holiday homes, caravans and motor
homes, boats
And for the continuous drying of:
• Warehouses, archives, laboratories
• Bathrooms, washing rooms & changing rooms.
Principle of operation:
The appliance works on the condensation principle
(see figure A: schematic diagram of the operating
principle).
The moist room air is sucked in by the ventilator and
fed through the evaporator and the condenser which
lies behind it.
Heat is extracted from the air in the cold evaporator.
The room air is cooled to below the dew point and the
water vapour in the air condenses as condensate or
frost on the lamellae of the evaporator.
The dehumidified, cooled air is warmed again at the
condenser (heat exchanger) and is blown out at a tem-
perature of approximately 5 °C above room temperature.
This treated, dryer air is then mixed with the ambient
air. Due to the continuous room air circulation through
the apparatus, the air humidity in the place of use is
reduced continually to the desired relative humidity.
Dependent on the air temperature and the relative air
humidity, the condensed water drops continually, or
B - 2
only during the periodic defrosting phases, into the
condensate pan and then into the condensate con-
tainer located below via the integrated outlet.
When the maximum fill state of the condensate con-
tainer is reached, the tank warning lamp on the op-
erating console lights and the apparatus switches off.
In the case of unattended continuous operation with
external condensate connection, the condensate is
continually drawn off via a hose connection (see the
section "Continuous operation with external conden-
sate connection").
A
A1
A. Schematic representation of the priciple of operation
A.1 Moist room air
A.2 Evaporator
A.3 Condenser
A.4 Drip tray
A.5 Water outlet

03. transportatIon oF apparatus

The appliance is equipped with lockable wheels and
grip recesses on both sides of the housing. Further-
more, the appliances can be stacked to save storage
space.
When transporting the appliance it must be kept
upright and secured by appropriate means such as
lashing straps.
Each time before transporting:
• B efore m oving t he a pparatus, s witch i t o ff a nd r emove
the mains plug from the socket.
• Then empty the condensate container. Please watch
out for subsequent dripping condensate.
• Do not pull the apparatus by its mains cable.
Operating Manual – Dehumidifier TTK 200
A2
A4
A5
A.6 Solenoid valve
A.7 Fan
A.8 Compressor
A.9 Dehumidified room air
A3
A9
A7
A6
A8
EN