04. set-up

For optimised, economical and safe operation of the
apparatus, you should in all cases observe the follow-
ing instructions (see also diagram B).
• The apparatus is to be placed upright and stable
to ensure unimpeded flow of the condensate into
the condensate container.
• If possible, place the apparatus in the centre of the
room to guarantee optimum air circulation.
• In all cases, the apparatus is to be kept at least 50
cm from walls.
• Make sure that air can be drawn in at the air inlet and
exhausted at the rear air outlet without hindrance.
• Do not operate the apparatus in the vicinity of
heaters or other sources of heat.
• Ensure t hat t he r oom t hat i s t o b e d ried o r d ehumidified
is closed off from the surrounding atmosphere.
• Ensure that doors and windows are closed, and
avoid frequently entering or leaving the room.
• If the apparatus is used in a dusty environment,
ensure that the applicable care & maintenance
measures are followed. See the section "Care and
maintenance".
Important information on electrical connection:
• In accordance with DIN VDE 0100, Part 704, the
apparatus must be connected to supply points with
earth leakage protection.
• I f the apparatus is used in wet areas such as laun-
dries, bathrooms or similar, it must be protected by
an inbuilt earth leakage protection switch that con-
forms with regulations.
EN
B
B. Set up
B.1 Keep windows closed
B.2 Keep doors closed
B.3 Keep apparatus at least 0,5m away from walls
B.4 Keep apparatus away from heaters or other sources of heat

05. commIssIonInG

Before each commission, or dependent on local re-
quirements, the intake and outlet openings must be
checked for foreign bodies and the intake filter must
be checked for fouling. Blocked or dirty grilles and
filters should be cleaned immediately, see the section
"care & maintenance".
Important instructions before commissioning:
• Cable extensions must have an adequate crosssection.
• Cable extensions must be either completely unrolled
from the drum or completely rolled!
• The condensate container must be inserted correctly.
• Economical dehumidification is no longer guaranteed
with this class of apparatus at room temperatures
of less than 2 °C and/or relative air humidity of less
than 35 %.
• Our product range contains special dehumidifiers
for use under such climatic conditions. Our staff will
be pleased to discuss your requirements with you.
Operating Manual – Dehumidifier TTK 200