TRP 100 M, TRP 100 W
11.8
Increasing the set point
The room heating device is delivered from the factory
with an adjustable temperature range of 7°C to 26° C.
The upper limit value can be increased (max. 32° C) or
lowered as required.
Press and hold the MENU key, the BACK key and
the ENTER key for five seconds.
SP display flashes.
Press the ENTER key. °C display flashes.
Press the ENTER key. Display 26 (limit value set at
the factory) flashes.
Press
or
to increase or lower the desired limit
value.
Press the ENTER key.
Confirm the BACK key to return to the standard
display.
11.9
Service information
NOTE
NOTE
This information is exclusively for service technicians.
The following information can be displayed:
UI number Service number display
CC number: Service number electronics
ID number: Service number heating device
Press and hold the ENTER key for five seconds.
INFO display flashes.
Press
or
to select the display Ui, CC or id.
Confirm the BACK key twice to return to the stand-
ard display.
NOTE
NOTE
Display id is a code with 12 digits.
The first 4 digits are shown on level 1.
Press  or  to select the next level (2,3).
www.dimplex.de/en
12. Warranty
This product is supplied with a two-year warranty
according to our terms of guarantee.
13. Note on disposal
Do not dispose of the unit with general
household waste. The device must be taken to
a local waste disposal plant.
14. Technical data
Model reference
Nominal voltage
Degree of protection
Dimensions (W x H x D)
Weight
Heat output
Nominal heat out-
put
Minimum heat
output (indicative)
Maximum contin-
P
uous heat output
Auxiliary electricity consumption
At nominal heat
output
At minimum heat
output
In standby mode
Type of control
Electronic room temperature controller with week program, window
monitoring, adaptive control of the heating start and operating time
limit
1810/B
TRP 100 M
1/N/PE, 230 V~, 50 Hz
IP25
465 x 1100 x 250
465 x 1088 x 250
mm
16,6 kg
P
1.0 kW
nom
P
1.0 kW
min
1.0 kW
max, C
0.0 W
el
max
0.0 W
el
min
el
0.5 W
SB
English
TRP 100 W
mm
10,1 kg
1.0 kW
1.0 kW
1.0 kW
0.0 W
0.0 W
0.5 W
EN-11