Technical Data For Cehk 345 Screw-In Heater - Dimplex CEHK 345 Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2
5)
Install the screw-in heater with the supplied flat gasket in the
flat sleeve or seal with hemp, PTFE or other similar sub-
stance. An a/f 60 spanner should be used for this.
Installation using pliers or similar is not permissible.
Fig. 1.4:
Screw-in heater completely installed
6)
Remove the upper part of the casing by undoing the four
screws. The connection cable must be threaded through the
supplied cable gland in the connection compartment of the
screw-in heater. Ensure the connection cable is large
enough.
7)
Establish the electrical connection (see chapter 1.3 on page
2). The supply voltage is obtained externally (e.g. subdistri-
bution) and the switching contact should be tapped from the
heat pump manager. Make sure that the connection voltage
is correct. Before initial commissioning, all of the connec-
tions must be checked against the circuit diagram once
more.
8)
The screw-in heaters are connected in star connection (tri-
ple-phase 3 - 400volts) as standard and designed for direct
control (see Fig. 1.1 on page 2, circuit diagram for triple-
phase connection). The star point must not be connected to
the protective conductor. The connection point for the pro-
tective conductor is marked separately.
9)
After the electrical connection has been established, the
casing must still be carefully rotated into the preferred posi-
tion. The casing seals must not be either shifted or dam-
aged. The original screws with washers must be used. Leak-
age caused by improper installation does not constitute a
warranty claim.
10) Then refill the buffer tank (heating circuit) and purge if re-
quired. Check the sleeve between the radiator and the tank
and put back the heat pump side panel.
EN-4
2
Technical data for
CEHK 345 screw-in
heater
Nominal heat output
Connection
Heater immersion depth
Unheated length
Thread length
Thread size
Pipe union length
Cap length
Degree of protection
Temperature setting range
Protection temperature limiter
(STL)
Maximum nominal pressure
Width
Height
Depth
Net weight
Tubular radiators material
Table 2.1: Technical Data
W
4500
3/PE, ~400 V, 50 Hz
(opt. 1/N/PE ~230 V)
mm
325
mm
120
mm
15
R 1 1/4"
mm
12
mm
115
IP 44
°C
Max. 75
98°C - 6k
(sensor temperature)
MPa
1 (10 bar)
(bar)
mm
88
mm
88
mm
470
kg
1.22
1.4404