Shut Appliance Down; Care And Maintenace; Spare Parts And Repairs; Troubleshooting - Birchmeier REC 15 AZ1 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Flow
Fanjet nozzle XR 8004 VS
Pressure
[bar]
1
2
3
4
5
6
* Operational state can't be attained

5. Shut appliance down

After use the appliance and pump lever must be emptied; never store the spray-liquid in the sprayer.(Please
ensure the correct disposal of any residue).
Rinse with clean water and pump dry.
Tip: This can also be done conveniently on tables or on floors when the pump lever is in the parking position.
VI Care and maintenace
Store the equipment away from the effects of frost. For storage, the spray-tube can be hooked onto the
retaining ring on the tank or on the pump lever.
The nozzle must be periodically cleaned or replaced.
Do not clean the nozzle with hard objects, nor blow through it using the mouth (danger of poisoning). The
most suitable cleaning device is a nail-brush or tooth-brush.
Gaskets are subject to wear and must be monitored regularly, and eventually replaced.
To dry the appliance, leave it standing in an open position.
Please be aware that the appliance may be subject to national requirements for regular inspection by
designated bodies, as provided for in Directive 2009/128/EC of the European Parliament.

1. Spare parts and repairs

If any part shows signs of damage or wear, replace it immediately. Use only BIRCHMEIER original parts (see
spare parts list).

2. Troubleshooting

The following check-list should help you when trouble-shooting minor malfunctions.
Repairs are only to be carried out by experts.
Pump lever
No pressure:
Leaking:
Tank
Leaking:
Insufficient pressure:
Spray pattern is poor:
Adjustable nozzle drips:
- 20 -
Spray angle 80°
[litres / minute]
0.91
1.29
1.58*
1.82*
2.04*
2.23*
O-ring on the piston defective  replace
Defective pump  replace
Defective pump seal  replace
Defective bellows or flat gasket  retighten (union nut) or replace
Flat gasket on the intake suction hose defective  replace
A Intake suction hose is blocked or defective  clean or replace
Adjustable nozzle is blocked  clean or replace
Defective gasket  replace

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rpd 15

Table des Matières