Problem-Solving By The Installer - Harvia Sentio QUBE-090 Instructions D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 58
Instructions for use for the user
p. 25/28

9. Problem-solving by the installer

Baking out of the heating rods
Moisture can accumulate in the heating rods in humid ambient conditions or dur-
ing long periods of non-use. This is a physical process and not a manufacturing
fault. Under certain circumstances, accumulation of moisture in the heating rods
can lead to the FI circuit breaker being triggered.
In this case, it is necessary to bake out the sauna heater under the supervision
of an electrician. To do this, the protective function of the FI circuit breaker must
be switched off. The baking out procedure takes approximately 10 minutes.
The safety function of the FI circuit breaker must subsequently be reactivated.
If the problem persists, consult your supplier.
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sentio qube-105Sentio qube-120Sentio qube-150

Table des Matières