Problem
The lamp does not work.
If your appliance is still not working properly after making
the above checks, contact the After Sales Centre.
Replacing the lamp
1. Disconnect the appliance.
2. Push the movable part to unhook the lamp cover (1).
3. Remove the lamp cover (2).
4. Replace the lamp with one of the same power and
specifically designed for domestic appliances only.
5. Install the lamp cover.
6. Connect the appliance.
7. Open the door. Make sure that the lamp comes on.
Technical data
Dimension
Rising Time
Voltage
Frequency
The technical information are situated in the rating plate
on the internal left side of the appliance and in the energy
label.
Installation
Caution! Read the "Safety Information" carefully for
your safety and correct operation of the appliance
before installing the appliance.
Possible cause
The appliance has no power. There is
no voltage in the mains socket.
The lamp is in stand-by.
The lamp is defective.
Height
1750 mm
Width
595 mm
Depth
658 mm
20 h
230 V
50 Hz
1
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Con-
tact the Service Center.
ZRB934XL
ZRB936XL ZRB936PW
ZRB934PW
1850 mm
595 mm
658 mm
20 h
230 V
50 Hz
Positioning
Install this appliance at a location where the ambient tem-
perature corresponds to the climate class indicated on the
rating plate of the appliance:
Solution
Connect a different electrical appliance
to the mains socket. Contact a qualified
electrician.
Close and open the door.
Refer to "Replacing the lamp".
2
2010 mm
595 mm
658 mm
20 h
230 V
50 Hz
ZRB940XL
ZRB940PW
21